MR Sensor Holding Plate
Be careful not to bend
this part.
this part.
Affix the MR
sensor block
sensor block
MR Sensor Hoding
Plate
Plate
MR Sensor Gap Sheet
Install the slant of MR sensor
gap sheet along the front
gap sheet along the front
Incline the portion A
to the bore side
to the bore side
Affix the MR sensor
block to the portion A,
eliminating a slack
at the portion B.
block to the portion A,
eliminating a slack
at the portion B.
Affix the MR sensor
setting tape
setting tape
Affix the MR sensor
flexible setting tape
flexible setting tape
Portion A
Portion A
Portion B
MR Sensor Block
Bent approx. 3°
MR Sensor
Holding Plate
Holding Plate
MR Sensor
Holding Plate
Holding Plate
Apply the
anti-diffusion
agent (A-20)
anti-diffusion
agent (A-20)
HELP22
Anti-diffusion agent (A-20): J-6082-611-A
1.
Bend the indicated portion of MR sensor holding plate about 3
°.
2.
Apply the anti-diffusion (A-20) to the indicated circumference of MR sensor holding plate.
3.
Affix the MR sensor flexible setting tape to the indicated portion of MR sensor holding plate.
4.
Affix the MR sensor setting tape to the MR sensor holding plate.
5.
Affix the MR sensor block to the MR sensor holding plate.
6.
Wind the MR sensor gap sheet as shown in the figure.
7.
Install the MR sensor holding plate along the front holding barrel.
8.
Push “portion A” of MR sensor holding plate to the bore.
Affix the MR sensor block to “portion B”, eliminating a slack.