SAL50F14Z - Sony Digital Camera Service Manual (repair manual). Page 28

Read Sony SAL50F14Z Service Manual online

4-14
SAL50F14Z (Planar 1,4/50 ZA) (Planar T*50mm F1.4 ZA SSM)
2.  Startup of Lens Adjustment Program (ActuatorCheckerSSM)
1)  Turn on the personal computer and the finished inspection JIG II.
2) Start up ACSSM-S-VerX.XX.exe  from an arbitrary folder.
Note:
•  At the first time using, the followings appear on the screen (Fig. 4-9-2).
It is required to ask HQ about the password for the Com/User Characteristic Number and the manufacturer/type name of the personal 
computer.
Ex.  Com/User Characteristic Number :  iYdDZfq9q
 
Personal Computer : 
SONY PCV-RZ33P
•  It is no need to input password to the computer once registered.
(The screen requires password does not appear.)
•  If the personal computer or the finished inspection JIG II is changed, the password and the Com/User Characteristic Number are 
changed.Therefore on the startup, the password input is required again
3) Input the password and click [OK [Ent]], the following appears on the screen (Fig. 4-9-3).
Fig. 4-9-2
Fig. 4-9-3
4-9-3. Initial Setting of Lens Adjustment Program (ActuatorCheckerSSM)
1. Start 
up ACSSM-S-VerX.XX.exe .
 
 Fig. 
4-9-4
2.  When the Japanese window appears, click the [Set up] button, change the language to English.
Note: 
Depending on the initial startup or setting made at the previous startup, the window differs.
3.  Set the following contents in the SETUP window.
MODEL 
Model to be adjustment in this time
Language English
State Final
 Table 
4-9-1
4.  Confirm that all of the items are set, and click [Save].
 
 Fig. 
4-9-5
5.  Click the [Finish] to close the SETUP window.
4-9-4. About Inspection Procedure of Lens Adjustment Program (ActuatorCheckerSSM)
The inspection method has the method of executing the method of inspecting the corresponding model as everything continues and the in-
spection of each item one by one.
Click [START] from the start up window when you inspect the corresponding model as everything continues.
Click the inspection of each item from the start up window, when you inspect one by one. 
4-10. FINISHED ADJUSTMENT/INSPECTION (ActuatorCheckerSSM)
4-10-1. Preparation
1)  Attach the checking lens to the equipment. (Refer to  4-9-2. Connection of Finished Inspection JIG II and Startup of Lens Adjustment 
Program (ActuatorCheckerSSM) ).
2)  Start up the lens adjustment program (ACSSM-S-VerX.XX.exe).
3)  Click [Setup] and perform the initial setting. (Refer to  4-9-3. Initial Setting of Lens Adjustment Program (ActuatorCheckerSSM) ).
Note:
  When the Multi Serial window opens, take the following actions.
 
Process No.:  You need not enter process number. 
 
Serial No.: 
When the mount block assy is replaced, enter a serial number.
 Fig. 
4-10-1