SAL500F80 - Sony Digital Camera Service Manual (repair manual). Page 20

Read Sony SAL500F80 Service Manual online

HELP
SAL500F80 (REFLEX 8/500) (500mm F8 Reflex)
HELP12
Adhesive bond (B-10): J-6082-612-A
1.
Apply the adhesive bond (B-10) in the width of 30 mm to the two instruction portions of the G1 stopper.
2.
Screw the G1 stopper into the helicoid unit, and tighten it 5 to 10 mm more from the place where the G1 retainer comes in contact
with the inside parts (G1+G3+G7 assy).
Note:
• After tightening, check that the helicoid unit does not clatter when the helicoid unit is shaken.
• Be sure not to tighten the G1 retainer too much.
3.
Perform the “4-2. Optical Axis Check/Adjustment”.
Apply the Adhesive Bond (B-10)
(30 mm width to threads)
Apply the Adhesive Bond (B-10)
(30 mm width to threads)
G1 Retainer