Read Sony SAL2470Z2 Service Manual online
4-4
SAL2470Z2 (Vario-Sonnar 2.8/24-70 ZA SSM II) (Vario-Sonnar T* 24-70mm F2.8 ZA SSM II)
4. Confirm that all of the items are set, and click [Save].
Fig.
4-1-10
5. Click the [Finish] to close the SETUP window.
4-1-6. About Inspection Procedure of Lens Adjustment Program (ACSSM-S-VerXXX)
The inspection method has the method of executing the method of inspecting the corresponding model as everything continues and the
inspection of each item one by one.
Click [START] from the start up window when you inspect the corresponding model as everything continues.
Click the inspection of each item from the start up window, when you inspect one by one.
inspection of each item one by one.
Click [START] from the start up window when you inspect the corresponding model as everything continues.
Click the inspection of each item from the start up window, when you inspect one by one.
4-2. APERTURE DIAMETER CHECK/ADJUSTMENT
4-2-1. Aperture Diameter Check
Equipment
• Luminance Box
• Camera (One of DSLR-A700, SLT-A37/A57/A58/A65/A77/A99)
• AE Master Lens
• Memory Card
• Personal Computer (Color Calculator 2 installed)
• Luminance Box
• Camera (One of DSLR-A700, SLT-A37/A57/A58/A65/A77/A99)
• AE Master Lens
• Memory Card
• Personal Computer (Color Calculator 2 installed)
1. Preparations
Note:
Confirm the checking lens by complete.
1) Install the memory card to the camera.
2) Set the equipment, camera and AE master lens as shown in Fig. 4-2-1.
2) Set the equipment, camera and AE master lens as shown in Fig. 4-2-1.
Luminance box
Luminance: EV12
Luminance: EV12
Camera
ISO: 100
Exposure Mode: M
Shutter Speed: 1/125
Aperture: F5.6
Focus Mode: MF
Metering: Center weighted
Preset white balance: Tungsten
D-R: OFF
ISO: 100
Exposure Mode: M
Shutter Speed: 1/125
Aperture: F5.6
Focus Mode: MF
Metering: Center weighted
Preset white balance: Tungsten
D-R: OFF
Master lens or checking lens
Zoom: Wide end (focal length: 24 mm)
Focus: Infinity end
Zoom: Wide end (focal length: 24 mm)
Focus: Infinity end
Shoot the center of the luminance surface
Fig.
4-2-1
3) Shoot the images under the following conditions and save them.
Note:
Shoot the center of the luminance surface three times with the AE master lens and checking lens.
Setting of Luminance box:
Luminance:
EV12
Setting of Lens:
Zoom:
WIDE end (focal length: 24 mm)
Focus:
Infinity end
Setting of Camera:
ISO:
100
Exposure Mode:
M
Shutter Speed:
1/125
Aperture:
F5.6
Focus Mode:
MF
Metering:
Center weighted
Preset white balance:
Tungsten
D-R:
OFF
2. Checking of Image
Note:
Check the image of both AE master lens and checking lens.
1) Start the Color Calculator 2.
Fig.
4-2-2
2) Read the image from the file menu.
⇒
Fig. 4-2-3