SAL24105 - Sony Digital Camera Service Manual (repair manual). Page 95

Read Sony SAL24105 Service Manual online

4-44
SAL24105 (3.5-4.5/24-105) (24-105mm F3.5-4.5)
4. In case of error display in the Focus Pattern (near position)
1)
When the error display and the NG display appear to the pop-up window, perform the work with caution so that setting the lens to the
near position can be done in more than 5 seconds and no more than 20 seconds.
• When the focus pattern error
Fig.4-10-24
Fig.4-10-25
• When the lens does not reach the infinity end near position seconds.
Fig.4-10-26
2)
Perform “2. Checking Method”again, repeat the inspection until “OK” appears on the pop-up window.
5. In case of error display in the Focus Pattern (infinity position (second try))
1)
When the error display and the NG display appear to the pop-up window, perform the work with caution so that setting the lens to the
infinity position can be done in more than 5 seconds and no more than 20 seconds.
• When the focus pattern error
Fig.4-10-27
Fig.4-10-28
• When the lens does not reach the infinity end infinity position seconds.
Fig.4-10-29
2)
Perform “2. Checking Method”again, repeat the inspection until “OK” appears on the pop-up window.