SAL24105 - Sony Digital Camera Service Manual (repair manual). Page 94

Read Sony SAL24105 Service Manual online

4-43
SAL24105 (3.5-4.5/24-105) (24-105mm F3.5-4.5)
4)
When the infinity position check finishes normally, the message “Move FOCUS to Near position at about 5sec.” is displayed on the
pop-up window.
Set the focus to the near position and press down the ENTER key.
Fig.4-10-19
5)
When the Near position check finishes normally, the message “Move FOCUS to Infinity position at about 5sec.” is displayed on the
pop-up window.
Set the focus to the infinity position and press down the ENTER key.
Fig.4-10-20
6)
When the infinity position check finishes normally, “OK” is displayed on the pop-up window, and press the ENTER key to return to
the initial window.
Fig.4-10-21
3. In case of error display in the Focus Pattern (infinity position (first try))
1)
When the error display and the NG display appear to the pop-up window, press the ENTER key to return to the initial window, and
perform “2. Checking Method”again.
Fig.4-10-22
Fig.4-10-23
2)
 Although the lens is positioned at the infinity position, if “NG” appears, confirm or perform the following.
• 4-10-1. Focus Brush Position Adjustment (Search Focus Adjustment Point)
• Cleaning of flexible pattern or the brush.
• Replaceing the brush.
• Rotating operation error of the focus ring (rotation speed is not suitable at a regulated speed.).
3)
Perform “2. Checking Method”again, repeat the inspection until “OK” appears on the pop-up window.