4-10. FOCUS BRUSH POSITION CHECK/ADJUSTMENT AND PATTERN CHECK
4-10-1. Focus Brush Position Adjustment (Search Focus Adjustment Point)
Equipment
• Personal Computer
• Finished Inspection JIG (AC100 V only)
• Lens Adjustment Program (ActuatorChecker.exe)
1. Preparations
1)
Remove the outer cover from the lens body.
Note:
Remove the outer cover little by little, inserting the Philips screw driver in the slit portion of outer cover.
Fig.4-10-1
2)
Connected to equipment with checking lens. (Refer to Section 4-1-3.)
3)
Start up of “ActuatorChecker.exe”.
4)
Click 
[Set up]
, and perform the initial setting. (Refer to Section 4-1-4.)
2. Adjusting Method
1)
Set the focus position to infinity position.
2)
Loosen two screws fixing the brush base plate.
Fig.4-10-2
Outer Cover Affixing Block
Outer Cover
Slit Portion
Screws