SAL135F28 - Sony Digital Camera Service Manual (repair manual). Page 74

Read Sony SAL135F28 Service Manual online

4-32
SAL135F28 (STF 2.8(T4.5)/135) (135mm F2.8 [T4.5] STF)
3)
The message “Move FOCUS to Infinity position, IRIS to [A]. Then push [ENTER].” is displayed on the pop-up window.
Set the focus to the infinity position, iris to A position and press down the ENTER key.
Fig.4-5-3
4)
When “OK” is displayed on the pop-up window, press the ENTER key to return to the initial window.
Fig.4-5-4
3. In case of error display in the ROM Data
1)
When the error display and the NG display appear to the pop up window, press the ENTER key to return to the initial window, and
perform “2. Checking Method” again.
Fig.4-5-5
Fig.4-5-6
2)
Although the focus is positioned at the infinity position, if the “NG” appears, confirm or perform the following.
• Cleaning of flexible pattern or the brush.
• Replacing the brush.
• Replacing the main flexible unit.
3)
Perform “2. Checking Method” again, repeat the inspection until “OK” appears on the pop-up window.
Page of 80
Display

Click on the first or last page to see other SAL135F28 service manuals if exist.