SAL135F28 - Sony Digital Camera Service Manual (repair manual). Page 70

Read Sony SAL135F28 Service Manual online

4-28
SAL135F28 (STF 2.8(T4.5)/135) (135mm F2.8 [T4.5] STF)
2. Checking Method
1)
Attach the checking lens to the flange back tester, and set the 1000 mm collimator.
Fig.4-4-3
2)
Set the distance scale tube of the checking lens to infinity end position and also set the stepless aperture to “A” while looking through
the microscope, and align the optical axis to the center of the chart image accurately.
3)
Turn the focusing knob of the tester until the chart image is the sharpest (red and green color areas are equal on the chart *).
*: Position in which the color of collimator chart changes from green into red and come into focus.
Also check the optical axis aligns with the chart center. (Refer to Fig.4-4-4.)
Note:
Figure shows example. The cause depends on individual lens.
Fig.4-4-4
4)
Calculate the flange back (f’F) of the checking lens using the following formula, and check that the specification of the Table 4-4-1 is
satisfied.
Flange back (f’F) of the checking lens = (Flange back gauge) + (Number of short-pointer revolution) + (Reading of long-pointer)
Specification
Focal-length
f’F (mm)
f (mm)
(Infinity position)
135
44.56 to 44.66
Table 4-4-1
5)
When the flange back (f’F) of the checking lens is out of specification of the Table 4-4-1, perform “4-4-2. Flange Back (f’F)
Adjustment”.
1000 mm collimator
Checking lens
Optical Alignment
Best alignment
Incorrect aligned
e.g. As the focusing knob is turned, the chart may appear blurry as illustrated.
The cause depends on individual lens.
Page of 80