1-6.  METHOD FOR ADJUSTING THE TEBURE REVISE
Make sure to confirm below after replacing the AS Slider B Assy T or the AS Holder Actuator Assy.
(1)  Remove the CV Rear Cover Assy (880), temporally mount the AS Slider Unit (863) mounted with the Imager Sensor, and then set up the camera body 
and hold the AS Slider Unit (863) as shown in figure.
 
(2)  Select “Slider Unit Check” of the adjustment software, and then confirm if the result is OK.
(3)  Select “Tebure Revise Adj.” of the adjustment software, and then confirm if the result is OK.
(4)  Mount the AS Slider Unit (863) to the camera.
 
1-5.  METHOD FOR CHECKING THE AS SLIDER UNIT (863)
Make sure to confirm below before replacing the AS Slider B Assy T or the AS Holder Actuator Assy.
(1)  Remove the CV Rear Cover Assy (880), and temporally mount the AS Slider Unit (863).
(2)  Set the AS Slider Unit (863) upwards as shown in figure, and put it on a stable place.
 
(3)  Select “Slider Unit Check” of the adjustment software, and then confirm the movement to the directions of Pitch and Yaw, and if an error occurs, 
replace it with the component part corresponding to the movement.
 