DSC-WX150 (serv.man2) - Sony Digital Camera Service Manual (repair manual). Page 9

Read Sony DSC-WX150 (serv.man2) Service Manual online

DSC-WX150_L2
1-7
1-10.   THREE TUBE LUBRICATING BLOCK ASSY AND GROUP 1 FRAME REPLACING METHOD
Claws
Sensors
FG Leaf
Spring
Claw
FPC Retainer
4. Disconnect the Flexible Board from the Connector on the LF-139 Flexible Board.
6. Disconnect the Flexible Board from the Connector on the LF-139 Flexible Board.
5. Peel off the FPC Tape.
Flexible Board
Flexible Board
FPC Tape
Connector
Connector
Ribs
Rib
Rib
Rib
Boss
Boss
Boss
Boss
LF-139 Flexible Board
Z Retainer
Screws
Screw
Sensor
7. Remove the LF-139 Flexible Board.
8. Remove the four screws and remove the Z Retainer and the Sensor.
Removal
1. Disengage the two claws and remove the FG Leaf Spring.
2. Remove the two Sensors.
3. Disengage the claw and remove the FPC Retainer.
A
A
Flexible Board
Flexible Board
Main Body
Main Body
Rotary Cam Tube
Rotary Tube
Stationary Tube Assy
Gear A
Gear A
Gear B
Gear Worm
Wheel
Rear Mirror
Plate
9. Detach the Rear Mirror Plate and remove the Gear Worm Wheel, Gear A, and Gear B.
10. Turn the Gear in the arrow direction to extend the Mirror Plate slightly.
11. Turn portion A in the arrow direction to TELE end and remove the Flexible Board from the hole in the Stationary Tube Assy.
12. Turn portion A in the arrow direction to WIDE end and detach the Main Body from the Stationary Tube Assy.
13. Remove the Main Body in the arrow direction.
14. 
Remove the Rotary Cam Tube from the Rotary Tube in the arrow direction.
Page of 21
Display

Click on the first or last page to see other DSC-WX150 (serv.man2) service manuals if exist.