DSC-W210, DSC-W215 (serv.man2) - Sony Digital Camera Service Manual (repair manual). Page 14

Read Sony DSC-W210 / DSC-W215 (serv.man2) Service Manual online

2-7
DSC-W210/W215_L2
Remove Barrier Assy by disengaging four claws.
Peel off release papers of Barrier Tapes.
Install Ornamental Ring A and press it lightly.
Installation
Affix two Barrier Tapes to Barrier Assy.
 
Note: 
The tape must not be wrinkled.
With four claws fitted in position, install the Barrier Assy.
Ornamental Ring A
Barrier Assy
Barrier Assy
A
Removal
1
  Turn on the power switch and extend the lens.
Detach the battery.
Pour a solvent such as alcohol from two places A to the tweezers or a needle shown below into a gap of Ornamental Ring A.
Remove while turning the Ornamental Ring A right and left.
Solvent
Claws
Claws
Tweezers
Ornamental Ring A
Barrier Assy
Barrier Tapes
Barrier Tape
Barrier Tape
Only one hook has
different shape.
Barrier Assy
Claws
Claws
2-4. BARRIER ASSY REPLACING METHOD
Page of 64
Display