AY-XP08CR - Sharp Air Conditioner Specification (repair manual)

ay-xp08cr specification
Model
AY-XP08CR
Pages
1 Few pages! See other manuals at the bottom of the first or last page.
Size
403.41 KB
Type
PDF
Document
Specification
Brand
Device
Air Conditioner
File
ay-xp08cr.pdf
Date

Read Sharp AY-XP08CR Specification online

2
AY-XP08CR
AY-XP10CR
AY-XP13CR
MODEL
INDOOR UNIT OUTDOOR UNIT INDOOR UNIT OUTDOOR UNIT INDOOR UNIT OUTDOOR UNIT
      ITEMS
AY-XP08CR AE-X08CR AY-XP10CR AE-X10CR AY-XP13CR AE-X13CR
Cooling capacity(Min. Max.) 
kW
2.2(0.9 _ 2.7)
2.8(0.9 _ 3.3)
3.6(0.9 _ 4.0)
Heating capacity(Min.~Max.) 
kW
3.2(0.9 _ 3.6)
3.7(0.9 _ 5.0)
4.8(1.0 _ 6.2)
Moisture removal(at cooling) 
Liters/h
0.6
0.7
1.2
Electrical data
Phase
Single
Rated frequency
Hz
50
Rated voltage
V
220 - 240
Cool
A
3.4 - 3.1
4.3 - 4.0
5.5 - 5.1
Rated current 
Heat
A
4.2 - 3.9
4.9 - 4.5
6.8 - 6.2
Cool
W
730
930
1200
Rated input 
Heat
W
 910
1050
1480
Cool
%
98 - 98
98 - 97
99 - 98
Power factor 
Heat
%
98 - 97
 97 - 97
99 - 99
Type
Hermetically sealed rotary type
Compressor
Model
DA89X1F-20F
Oil charge
Ester oil VG68 370ml
Evaporator
Louvre Fin and Grooved tube type
Corrugate Fin and Grooved tube type
Control
Capillary tube
Refrigerant volume
750g
770g
870g
(R-410A)
Noise level
High
dB(A)
33
43
36
43
38
48
(at cooling)
Med.
dB(A)
29
32
33
-
Low
dB(A)
27
27
29
-
Drive
Direct drive
Air flow quantity
High
m
3
/min.
7.5
28
9.8
27.7
9.4
30
 (at cooling)
Med.
m
3
/min.
6.5
8.0
8.0
Low
m
3
/min.
5.1
6.0
6.5
Fan
Cross flow fan Propeller fan Cross flow fan Propeller fan Cross flow fan Propeller fan
Connections
Refrigerant coupling
Flare type
Refrigerant tube size Gas, Liquid
 3/8", 1/4"
Drain piping mm
O.D  ø 18
Others
Compressor: Compressor thermistor
Safety device
Fan motors: Thermal fuse
Fuse, Micro computer control
Air filters
Polypropylene net (Washable)
Width
mm
815
780
815
780
815
780
Net dimensions
Height
mm
278
540
278
540
278
540
Depth
mm
198
269
198
269
198
269
Net weight
kg
9
33
10
33
10
37
 Note: The condition of star " 
 
" marked item are ‘ISO5151’ : 1994(E), condition T1.
SPECIFICATIONS
Display

Download Sharp AY-XP08CR Specification

Here you can read online and download Sharp AY-XP08CR Specification in PDF. AY-XP08CR specification will guide through the process and help you recover, restore, fix, disassemble and repair Sharp AY-XP08CR Air Conditioner. Information contained in service manuals typically includes schematics / circuit diagrams, wiring diagrams, block diagrams, printed wiring boards, exploded views, parts list, disassembly / assembly, pcb.