Read Sony DSC-TX30 (serv.man2) Service Manual online
DSC-TX30_L2
1-6
– ENGLISH –
4. Check that no dust is present on the vacuum pad and the speaker seat of the unit, and push the vacuum pad perpendicularly against the center of
the speaker seat to stick the vacuum pad.
Radiation sheets B
Speaker seat
OK
Tilt
NG
Air leak
Caution :
Keep vacuum pad vertically by touching with finger.
Do not keep pressing it to the camera.
Do not keep pressing it to the camera.
Do not touch the tube during the measurement, or measurement
value may be changed.
value may be changed.
Perform the measurement under no vibration.
It may cause the air-leak under the condition with vibration.
It may cause the air-leak under the condition with vibration.
Test hole
5. Wait 30 seconds with keeping the pressure at near -5.0 kPa.
6. Wait 30 seconds with setting air switch to “close”, and record the indicated value (C).
7. Leave the air leak tester for another 60 seconds, and record the indicated value (D).
6. Wait 30 seconds with setting air switch to “close”, and record the indicated value (C).
7. Leave the air leak tester for another 60 seconds, and record the indicated value (D).
Caution: Do not open the battery cover for 120 seconds after the leak test.
-40.0kPa
0kPa
30sec
30sec
60sec
-45.0kPa
-50.0kPa
-0.0kPa
FFF
-5.0kPa
-10.0kPa
Air
pressure
pressure
Indicated
value
value
Air switch: open
Air switch: close
Measurement
(C)
(D)
Measure this amount of change.
Displayed values at measurement
points (C) and (D) are entered in
"
Displayed values at measurement
points (C) and (D) are entered in
"
AirLeak_CheckTool.exe
"
to determine them.
1-4-1-3. Deciding Measured Values
Make decision of measured values using “
AirLeak_CheckTool.exe
”.
Enter each measured value in indicated locations of the
window
.
Enter the value measured by the
air leak tester after 60 seconds.
air leak tester after 60 seconds.
Enter the value measured by
the unit after 120 seconds.
the unit after 120 seconds.
Enter the value measured by
the air leak tester after 120 seconds.
the air leak tester after 120 seconds.
Enter the value measured
by the unit after 60 seconds.
by the unit after 60 seconds.
After each value has been entered,
click “Judge!” button, then
decision result is displayed in the
window
shown below.
The changed portions from
Ver. 1.0 are shown in blue.
Ver. 1.0 are shown in blue.
Ver. 1.1 2013.05