DSC-TX30 (serv.man2) - Sony Digital Camera Service Manual (repair manual). Page 8

Read Sony DSC-TX30 (serv.man2) Service Manual online

DSC-TX30_L2
1-5
– ENGLISH –
1-4.  AIR-LEAK TEST 
Ordinary checking procedure is no longer used. Be sure to follow the new checking proce-
dure described below.
1-4-1. Inspection Procedure (Compressor Type)
1-4-1-1. Measuring Reference Values of the Tester
Before starting the air leak test, check reference values of the compressor-type air leak tester.
Checking procedure
Conduct the air leak test with the air leak tester placed on a flat plate (such as a glass plate on the table).
1.  Turn on the air-leak tester.
2.  Hold the vacuum pad on flat surface, set the air switch to “open”, and adjust the pressure to around -5.0 by turning the pressure adjustment knob.
 
Inspection pressure: -45.0 ± 3.0 kPa
 
3.  Check that no dust is present on the vacuum pad and the flat plate (such as a glass plate on the table), and push the vacuum pad perpendicularly 
against the flat plate to stick the vacuum pad.
 
Glass plate
OK
Tilt
NG
Air leak
Caution :
Keep vacuum pad vertically by touching with finger. 
Do not keep pressing it to the glass plate.
Do not touch the tube during the measurement, or measurement
value may be changed.
Perform the measurement under no vibration.
It may cause the air-leak under the condition with vibration.
4.  Wait 30 seconds with keeping the pressure at near -5.0 kPa.
5.  Wait 30 seconds with setting air switch to “close”, and record the indicated value (A).
6.  Leave the air leak tester for another 60 seconds, and record the indicated value (B).
 
-40.0kPa
0kPa
30sec
30sec
60sec
-45.0kPa
-50.0kPa
-0.0kPa
FFF
-5.0kPa
-10.0kPa
Air
pressure
Indicated
value
Air switch: open
Air switch: close
Measurement
(A)
(B)
Measure this amount of change.
Displayed values at measurement 
points (A) and (B) are entered in 
"
AirLeak_CheckTool.exe
to determine them.
1-4-1-2. Measuring the Unit
1.  Turn on the air-leak tester.
2.  Hold the vacuum pad on flat surface, set the air switch to “open”, and adjust the pressure to around -5.0 by turning the pressure adjustment knob.
 
Inspection pressure: -45.0 ± 3.0 kPa
 
3.  Stick two radiation sheets B (4-174-010-01) to the two microphone seats.
 
Radiation sheets B
Microphone seats
The changed portions from
Ver. 1.0 are shown in blue.
Ver. 1.1 2013.05
Page of 39
Display