DSC-T50 (serv.man4) - Sony Digital Camera Service Manual (repair manual). Page 24

Read Sony DSC-T50 (serv.man4) Service Manual online

6-22
DSC-T50_ADJ
7.
AWB 3200K-5800K Standard Data Input
[Adjustment method]
1) Start the AWB Adjustment Program (T50AwbAdjustment.exe).
2) Click the [Connect] button to set the camera to the adjustment
mode.
Fig. 6-1-35
3) Adjust the mode switch of the camera to “CAMERA” and set
MACRO mode. Shoot the 9 colors chart with the zoom at WIDE
end.
4) Adjust the camera direction and distance to set the picture
frame. (Refer to 5. Picture Frame Setting)
5) Click the [AWB 3200K-5800K Standard Data Input] button.
Fig. 6-1-36
6) A picture captured by the camera is displayed on the screen,
and the adjustment and checking are performed.
Fig. 6-1-37
Note:
If the following message is displayed, the picture frame
setting is faulty. Check the picture frame, and then perform
readjustment.
Fig. 6-1-38
7) Upon successful completion of the adjustment, the following
message is displayed. Click the [OK] button.
Fig. 6-1-39
8) Perform the “Camera Adjustment 5” successively without turn-
ing off the power switch of the camera.
Page of 38
Display