DSC-T1 (serv.man2) - Sony Digital Camera Service Manual (repair manual). Page 26

Read Sony DSC-T1 (serv.man2) Service Manual online

6-24
DSC-T1
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
60
01
00
Set the data.
2
60
E1
00
Set the data.
3
60
12
00
Set the data.
4
60
14
00
Set the data.
5
75
09
Set the data memorized at
“Preparation”.
6
77
F6
Set the data memorized at
“Preparation”.
7
77
F7
Set the data memorized at
“Preparation”.
8
77
F2
Set the data memorized at
“Preparation”.
9
77
72
Set the data memorized at
“Preparation”.
10
60
05
00
Set the data.
11
75
17
Set the data memorized at
“Preparation”.
12
75
18
Set the data memorized at
“Preparation”.
13
75
19
Set the data memorized at
“Preparation”.
14
75
1A
Set the data memorized at
“Preparation”.
15
75
1B
Set the data memorized at
“Preparation”.
16
Perform next adjustments.
If finish the camera system
adjustments, release the data
setting.
(See “1. Data Setting during
Camera System Adjustments”.)
14. Color Reproduction Adjustment
Adjust the color reproduction of yellow, red, blue and cyan so that
proper color reproduction is produced.
Mode
STILL ( 
 )
Subject
Color bar chart (Standard picture frame)
Measurement Point
Data of page: 6E, address: 4F
Measuring Instrument
Adjustment Page
6E
Adjustment Address
60 to 67
Specified value
00
Note1:
If the data of page: 60, address: 02 is “01”, select page: 60, address:
01, and set data: 00.
Switch setting:
ZOOM ........................................................................... WIDE end
VIDEO OUT (SET UP of Menu) ......................................... NTSC
Adjusting method:
Order Page Address Data
Procedure
1
Install the color bar chart.
2
Check that “1. Data Setting during
Camera System Adjustments” is
performed.
3
Check the picture frame. If
deviated, perform “5. Picture
Frame Setting”.
4
7A
00
Read the data, and this data is
named D
00
.
5
7A
00
00
Set the data.
6
6E
4F
FF
Set the data.
7
60
01
AB
Set the data.
8
60
01
A9
Set the data.
9
Wait until the color of the screen
stops changing.
10
60
02
Read the data, and check it is “01”.
(Note2)
11
6E
4F
Read the data, and check it
satisfies the specified value.
Note2:
The adjustment data will be automatically input to page: 6E,
address: 60 to 67.
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
60
01
00
Set the data.
2
7A
00
Set the data memorized at
“Adjusting method”.
3
Save the data.
4
Wait for 2 sec.
5
Perform “Color Reproduction
Check”.
If finish the camera system
adjustments, release the data
setting.
(See “1. Data Setting during
Camera System Adjustments”.)
Page of 40