DSC-S85 (serv.man2) - Sony Digital Camera Service Manual (repair manual). Page 21

Read Sony DSC-S85 (serv.man2) Service Manual online

– 21 –
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
Perform “Data setting during
camera system adjustments”.
(Refer to page 5-14)
3
6
90
00
4
6
91
00
5
6
92
FF
6
6
93
FF
7
6
2C
01
8
6
01
79
Press PAUSE button.
9
6
07
Check the data changes to “01”.
10
6
01
67
Press PAUSE button.
11
Check the flashing of strobe
light.
12
6
02
Check the data changes to “01”.
13
6
01
00
Press PAUSE button.
14
6
01
67
Press PAUSE button.
15
Check the flashing of strobe
light.
16
6
02
Check the data changes to “01”.
17
6
01
00
Press PAUSE button.
18
7
03
05
Press PAUSE button.
19
6
01
B9
Press PAUSE button.  (Note 7)
20
Check the flashing of strobe
light.
21
6
02
Check the data changes to “01”.
22
6
01
00
Press PAUSE button.
23
7
03
04
Press PAUSE button.
24
6
01
67
Press PAUSE button.
25
Check the flashing of strobe
light.
26
6
02
Check the data changes to “01”.
27
F
64
Check that the data satisfies
the Y level data satisfied
value. (Note 4)
28
0
03
02
29
1
Check the R-Y and B-Y level
data (Note 5) satisfies the
specified value.
Note 7:
The adjustment data will be automatically input to
page: F, address: 4D, 4E, 64 and 69 to 6B.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
0
03
00
2
6
01
00
Press PAUSE button.
3
6
2C
00
4
6
92
00
5
6
93
00
6
Release the data setting
performed at step 2 .
(Refer to page 5-14)
7
0
01
00
17. Strobe White Balance Adjustment
Adjust the white balance when the strobe light flashed.
Mode
CAMERA
Subject
Flash adjustment box (Note 3)
(1.0 m from the front of the lens)
Adjustment Page
F
Adjustment Address
4D, 4E, 64, 69 to 6B
Specified Value
Y level data: 60 to 94 (Note 4)
R-Y level data: FA to FF or 00 to 06
(Note 5)
B-Y level data: FA to FF or 00 to 06
(Note 5)
Note 1:
Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
Note 2:
Perform this adjustment in the Flash adjustment box.
Note 3:
Refer to “4. Preparing the Flash adjustment box”. (See
page 5-7)
Note 4:
Displayed data of page: F, address: 64, of the adjusting
remote commander.
F:XX:64
Y level data
Note 5:
The right four digits of the page: 1 displayed data of the
adjusting remote commander.
1:XX:XX
B-Y level data
R-Y level data
Note 6:
“Strobe White Balance Adjustment” is available only
once after the power is turned on. Turn the power off,
then on again if the adjustment is retried.
Switch setting:
1)  FLASH ........................ ON
Page of 24
Display

Click on the first or last page to see other DSC-S85 (serv.man2) service manuals if exist.