– 19 –
15. CCD White Defect Compensation
Mode
CAMERA
Subject
Not required
Measurement Point
Displayed data of page: 6,
address: 55
Measuring Instrument
Adjusting remote commander
Adjustment Page
7
Adjustment Address
88 to A3
Note 1:
Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
Perform “Data setting during
camera system adjustments”.
(Refer to page 5-14)
3
F
DE
Note down the data.
4
F
DE
1E
Press PAUSE button.
5
F
E3
Note down the data.
6
F
E3
0E
Press PAUSE button.
7
6
01
8B
Press PAUSE button. (Note 2)
8
6
02
Check the data changes to “01”.
9
6
55
Check the data.
00 to 7F: Normal
80 to FF: Defective
10
6
01
00
Press PAUSE button.
11
F
DE
0F
Press PAUSE button.
12
F
E3
60
Press PAUSE button.
13
6
01
87
Press PAUSE button.
14
6
02
Check the data changes to “01”.
15
6
55
Check the data changes to “00”.
Note 2:
The adjustment data will be automatically input to
page: 7, address: 88 to A3.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE button.
2
F
E3
Set the data noted down at
step 5, and press PAUSE
button.
3
F
DE
Set the data noted down at
step 3, and press PAUSE
button.
4
Release the data setting
performed at step 2 . (Refer
to page 5-14)
5
0
01
00
Ver. 1.1  2001. 08