DSC-S85 (serv.man2) - Sony Digital Camera Service Manual (repair manual). Page 15

Read Sony DSC-S85 (serv.man2) Service Manual online

– 15 –
11. Smear Compensation Adjustment
Adjust the smear compensation data from white balance standard
data at 3200K.
Mode
CAMERA
Subject
Clear chart
(Color reproduction adjustment
frame with the zoom lens at
WIDE end)
Adjustment Page
F
Adjustment Address
9D, 9E
Note 1:
 Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
Note 2:
Refer to “Picture Frame Setting” for YH and YL.
Note 3:
“Smear Compensation Adjustment” is available only once
after the power is turned on. Turn the power off, then on
again if the adjustment is retried.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
Perform “Data setting during
camera system adjustments”.
(Refer to page 5-14)
3
6
2C
01
4
6
90
00
5
6
91
00
6
6
92
YL
(Note 2)
7
6
93
YH
(Note 2)
8
6
01
79
Press PAUSE button.
9
6
07
Check the data changes to
“01”.
10
6
01
00
Press PAUSE button.
11
6
01
11
Press PAUSE button.
12
6
13
AE
Press PAUSE button.
13
6
01
D1
Press PAUSE button. (Note 4)
14
6
02
Check the data changes to “01”.
Note 4:
The adjustment data will be automatically input to
page: F, address: 9D and 9E.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE button.
2
6
13
00
Press PAUSE button.
3
6
2C
00
4
6
92
00
5
6
93
00
6
Release the data setting
performed at step 2. (Refer to
page 5-14)
7
0
01
00
Page of 24
Display