5.
AWB 3200K-5800K Standard Data Input
[Adjustment method]
1) Start the AWB Adjustment Program (S40AwbAdjustment.exe).
2) Click the 
[Connect]
  button to set the camera to the adjust-
ment mode.
Fig. 6-1-23
3) Set the mode switch to “CAMERA”, and shoot the 9 colors
chart with the zoom at WIDE end.
4) Adjust the camera direction and distance to set the picture
frame. (Refer to 3. Picture Frame Setting)
5) Click the 
[AWB 3200K-5800K Standard Data Input]
 button.
Fig. 6-1-24
6) A picture captured by the camera is displayed on the screen,
and the adjustment and checking are performed.
Fig. 6-1-25
Note:
If the following message is displayed, the picture frame
setting is faulty. Check the picture frame, and then perform
readjustment.
Fig. 6-1-26
7) Upon successful completion of the adjustment, the following
message is displayed. Click the 
[OK]
 button.
Fig. 6-1-27
8) Perform the “CAMERA Adjustment 4” successively without
turning off the power switch of the camera.