6-27
DSC-R1_ADJ
11. CAMERA Adjustment 6
[Automatic Adjustment Program execution items and
sequence]
1. Data Setting during Camera Adj.
2. C MOS Linearity Check
3. Release of Data Setting during Camera Adj.
[Adjusting method]
1) Click the 
[Start]
 button of the CAMERA Adjustment 6.
2) The Automatic Adjustment Program executes the “1. Data Set-
ting during Camera Adj.”.
3) Upon successful completion of “1. Data Setting during Cam-
era Adj.”, the following screen is displayed. Set the zoom to
the TELE end.
Fig. 6-1-60
4) If the 
[OK]
  button is clicked, the following message is dis-
played. Set the subject in accordance with the message.
Fig. 6-1-61
5) Click the 
[OK]
 button, and the “2. C MOS Linearity Check”
and “3. Release of Data Setting during Camera Adj.” will be
executed.
6) Upon successful completion of all items of the CAMERA
Adjustment 6, the following message is displayed. Click the
[OK]
 button.
Fig. 6-1-62
With the zoom at the TELE end, 
the data becomes maximum value.