Read Sony DSC-P71 / DSC-P71M Service Manual online
5-18
DSC-P71/P71M
4.
F No. Compensation
RadarW
RadarW
RadarW
Compensate the unevenness of the iris meter sensitivity.
Mode
CAMERA
Subject
Clear chart
(Standard picture frame with the
zoom lens at WIDE end)
(Standard picture frame with the
zoom lens at WIDE end)
Adjustment Page
F
Adjustment Address
5E to 64
Note 1:
Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
If not, turn the power of unit OFF/ON.
Adjusting method:
Order Page Address Data
Procedure
1
Perform “Data setting during
camera system adjustment”.
(Refer to page 5-13)
camera system adjustment”.
(Refer to page 5-13)
2
Perform “Picture Frame
setting”.
(Refer to page 5-14)
setting”.
(Refer to page 5-14)
3
6
01
BB
Press PAUSE button.
(Note 2)
(Note 2)
4
6
02
Check the data changes to
“01”.
“01”.
Note 2:
The adjustment data will be automatically input to page:
F, address: 5E to 64.
F, address: 5E to 64.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE button.
2
Release the data setting
performed at step 1.
(Refer to page 5-13)
performed at step 1.
(Refer to page 5-13)
5.
Mechanical Shutter Adjustment
RadarW
RadarW
RadarW
Adjust the period which the mechanical shutter is closed, and com-
pensate the exposure.
pensate the exposure.
Mode
CAMERA
Subject
Clear chart
(Standard picture frame with the
zoom lens at WIDE end)
(Standard picture frame with the
zoom lens at WIDE end)
Adjustment Page
F
Adjustment Address
B8 to D7
Note 1:
Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
If not, turn the power of unit OFF/ON.
Adjusting method:
Order Page Address Data
Procedure
1
Perform “Data setting during
camera system adjustment”.
(Refer to page 5-13)
camera system adjustment”.
(Refer to page 5-13)
2
Perform “Picture Frame
setting”.
(Refer to page 5-14)
setting”.
(Refer to page 5-14)
3
6
01
AD
Press PAUSE button.
(Note 2)
(Note 2)
4
6
02
Check the data changes to
“01”.
“01”.
5
6
AB
Check the data is “00”.
Note 2:
The adjustment data will be automatically input to page:
F, address: B8 to D7.
F, address: B8 to D7.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE button.
2
Release the data setting
performed at step 1.
(Refer to page 5-13)
performed at step 1.
(Refer to page 5-13)
Click on the first or last page to see other DSC-P71 / DSC-P71M service manuals if exist.