DSC-P71, DSC-P71M - Sony Digital Camera Service Manual (repair manual). Page 121

Read Sony DSC-P71 / DSC-P71M Service Manual online

5-16
DSC-P71/P71M
2.
Flange Back Adjustment
RadarW
RadarW
RadarW
RadarW
RadarW
(Using the flange back adjustment chart and
Subject More than 500 m Away)
The inner focus lens flange back adjustment is carried out auto-
matically. In whichever case, the focus will be deviated during
auto focusing/manual focusing.
2-1. Flange Back Adjustment (1)
Mode
CAMERA
Subject
Flange back adjustment chart
(2.0 m from the front of lens)
(Luminance: 300 to 400 lux)
Measurement Point
 Check operation on monitor TV
Measuring Instrument
Adjustment Page
F
Adjustment Address
18 to 3E, 52, 53
Note 1:
Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
Preparations before adjustments:
1) Place the Flange back adjustment chart 2.0 m from the front
of the lens.
2) Check that the center of Flange back adjustment chart meets
the center of shot image screen with the zoom lens at TELE
end and WIDE end respectively.
Adjusting method:
Order Page Address Data
Procedure
1
Perform “Data setting during
camera system adjustment”.
(Refer to page 5-13)
2
6
01
13
Press PAUSE button.
3
6
01
15
Press PAUSE button.
(Note 2)
4
6
02
Check the data changes to
“01”.
5
F
3E
Check the data.
00: Normal
01 to FF: Defective
6
F
24
Check the data.
0A to 7F: Normal
00 to 09, 80 to FF: Defective
Note 2:
The adjustment data will be automatically input to page:
F, address: 18 to 3E, 52 and 53.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE button.
2
Release the data setting
performed at step 1.
(Refer to page 5-13)
3
Perform “Flange Back
Adjustment (2)”.
2-2. Flange Back Adjustment (2)
Perform this adjustment after performing “Flange Back Adjust-
ment (1)”.
Mode
CAMERA
Subject
Subject more than 500 m away
(Subject with clear contrast such
as buildings, etc.)
Measurement Point
Check operation on monitor TV
Measuring Instrument
Adjustment Page
F
Adjustment Address
18 to 3E, 52, 53
Adjusting method:
Order Page Address Data
Procedure
1
Set the zoom lens to the
TELE end and expose a
subject that is more than 500
m away. (Note 1)
2
Perform “Data setting during
camera system adjustment”.
(Refer to page 5-13)
3
6
01
13
Press PAUSE button.
4
Place ND filter on the lens so
that the optimum image is
obtain.
5
6
01
29
Press PAUSE button.
(Note 2)
6
6
02
Check the data changes to
“01”.
7
F
3E
Check the data.
00: Normal
01 to FF: Defective
8
F
24
Check the data.
0A to 7F: Normal
00 to 09, 80 to FF: Defective
Note 1:
Subject with clear contrast such as building, etc.
Nearby subjects less than 500 m away should not be in
the screen.
Note 2:
The adjustment data will be automatically input to page:
F, address: 18 to 3E, 52 and 53.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE button.
2
Release the data setting
performed at step 2.
(Refer to page 5-13)
3
Perform “Flange Back
Check”.
Page of 127
Display

Click on the first or last page to see other DSC-P71 / DSC-P71M service manuals if exist.