DSC-HX50, DSC-HX50V (serv.man2) - Sony Digital Camera Service Manual (repair manual). Page 4

Read Sony DSC-HX50 / DSC-HX50V (serv.man2) Service Manual online

DSC-HX50/HX50V_L2
1-1
1. SERVICE  NOTE
1-1.  PRECAUTION ON REPLACING THE SY-1018 BOARD
DESTINATION DATA
When you replace to the repairing board, the written destination data of repairing board also might be changed to original setting.
Start the Adjust Manual in the Adjust Station and execute the “DESTINATION DATA WRITE”.
RESTORE DATA
When you replace to the repairing board, get the data from the former one.
Start the Adjust Manual in the Adjust Station and perform “RESTORE DATA” to get the data. 
The data getting for this model is as follows.
• PRODUCT ID & USB SERIAL No.
• Angular Velocity Sensor Sensitivity adjustment
• AWB standard data input & check, Color reproduction check
Deleting Network Settings
Before replacing the SY-1018 board, delete the customer’s network settings.
Start the Adjust Manual in the Adjust Station and execute the “NETWROK SETTING RESET”.
USB Serial No. and Product ID
The unit is shipped after an ID (USB Serial No.) unique to each unit and an ID (Product ID) unique to each model have been written.
These IDs have not been written in a new board for service, and therefore they must be entered after the board replacement.
After the board has been replaced with a board for service, start the Adjust Manual in the Adjust Station and execute the “PRODUCT ID & USB 
SERIAL No. INPUT” and enter these IDs.
Note:  A newly entered Product ID is not always equal to the ID before board replacement. If the new ID differs from the previous ID, it may cause a difference 
from the ID registered by the customer.
Update of MAC Address
When a board that contains Wi-Fi has been replaced or when replacing a board that contains the main IC (CPU), the IC’s unique number (MAC ad-
dress) must be reloaded.
Perform the following procedure to reload the IC’s unique number (MAC address).
1.  Download the latest-version Adjust Manual from the TISS homepage.
2.  Install the downloaded Adjust Manual.
3.  Start the Adjust Manual, and execute “Wireless LAN check” on the ADJUST tab.
4.  Perform the following operations for the unit to initialize.
 MENU 
→   (Settings) →   (Main Settings) → [Initialize] → (Network Settings) → [OK] → ●
5.  Perform the following operations for the unit to display MAC address.
 MENU 
→   (Settings) →   (Network Settings) → [Disp MAC Address] → ●
6.  Confirm that the displayed MAC address has been updated.
Applicable parts
•  SY-1018 BOARD, COMPLETE (SERVICE)
Note: The LOAD AND WRITE function in ADJUSTMENT DATA BACKUP on the DATA tab in the Adjust manual overwrites all data of the unit.
 
Therefore, the MAC address updated during the above procedure is also overwritten.
Perform the above operations after all work has been done.
After the replacement and repair, the MAC address is changed, and thus the re-setting for connection devices is required. Accordingly, print out the 
flyer given at the manual and attach it to the set when returning the set to customer.
– ENGLISH –
Angular Velocity Sensor
When you replace to the repairing board, write down the sensitivity displayed on the angular velocity sensor (SE401).
Start the Adjust Manual in the Adjust Station and execute the “Angular velocity sensor sensitivity adj”.
SE401
Y  P
Y P
P: PITCH sensor sensitivity
Y: YAW sensor sensitivity
Type B:
Type A:
SY-1018 BOARD (SIDE A)
Note: The sensor sensitivity of SE401 of SY-1018 board is written only repair parts.
1-2.  ADDITION OF DESTINATION DATA FILE
If the Destination Data file included in the Adjust manual is old, “DESTINATION DATA WRITE” cannot be executed in some cases.
In that case, download a new Destination Data file from the TISS homepage according to the following procedure.
Note 1:  To perform Destination Data Write for this model, the Adjust manual of the DSC-WX50 series must have been installed.
 
Install the Adjust manual of the DSC-WX50 series in advance.
Note 2:  The actual image may differ from the image shown above.
1)  If the Destination Data file in the Adjust manual in use is old, the window shown in Fig. 1 is displayed.
 
Click the [OK] button.
 
 Fig. 
1
2)  The Destination Data Write window opens.
 
Check the version of the Destination Data file retained in the Adjust manual.
 
Destination Ver. window
Page of 43
Display

Click on the first or last page to see other DSC-HX50 / DSC-HX50V (serv.man2) service manuals if exist.