DSC-H5 (serv.man3) - Sony Digital Camera Service Manual (repair manual). Page 19

Read Sony DSC-H5 (serv.man3) Service Manual online

6-17
DSC-H5_ADJ
2.
Wide Limit Adjustment
Adjustment to remove variations at the wide end of the inner fo-
cus lens.
Adjustment Page
6F
Adjustment Address
18, 19
2-1. Adjusting method when the lens is replaced:
Adjusting method:
Order Page Address
Data
Procedure
1
00
01
01
Set the data.
2
40
38
00
Set the data.
3
6F
18
Set the data. (Note)
4
6F
19
Set the data. (Note)
5
7C
16
01 
t 00
Change the data.
(The data is OK if it is “00”.)
6
Save the data.
7
80
34
Check the data is “00”.
8
80
30
Check the data is “00”.
9
Perform “Flange Back
Adjustment”.
Note: The data of page: 6F, address: 18 and 19, that are set in the
Orders 3 and 4 as described above, are shown on the data
sheet supplied with the replacement lens for repair.
Set the upper single byte of the 2-byte data shown on the
sheet to address: 18, and the lower byte of the data to the
address: 19.
Fig. 6-1-19
2-2. Adjusting method when replacement of lens is
not required and the SY-150 board is replaced:
When the data of page: 6F, address: 18 and 19 can be
read from the defective SY-150 board before replace-
ment, and both of the data are not “00”:
Adjusting method:
Order Page Address
Data
Procedure
1
00
01
01
Set the data.
2
40
38
00
Set the data.
3
6F
18
Set the previous data
4
6F
19
Set the previous data
5
7C
16
01 
t 00
Change the data.
(The data is OK if it is “00”.)
6
Save the data.
7
80
34
Check the data is “00”.
8
80
30
Check the data is “00”.
9
Perform “Flange Back
Adjustment”.
When the data of the page: 6F, address: 18 and 19 can
be read out from the defective SY-150 board before
replacing it, and both of the data are “00”:
1) Replace the lens with the replacement lens and perform “2-1.
Adjusting method when the lens is replaced”.
When the data of page: 6F, address: 18 and 19 cannot
be read from the defective SY-150 board:
1) Replace the lens with the replacement lens and perform “2-1.
Adjusting method when the lens is replaced”.
Note: The data of page: 7C, address: 16, that is set in the Order 5
of the adjusting method of 2-1 or 2-2, is “01” when shipped
from the factory. Let the data remain “00” after completion
of the service adjustment.
Data for Page: 6F, Address: 19
The right four digits of the seal (2-byte data)
Data for Page: 6F, Address: 18
XX
 
XXXX