DSC-H5 (serv.man3) - Sony Digital Camera Service Manual (repair manual). Page 18

Read Sony DSC-H5 (serv.man3) Service Manual online

6-16
DSC-H5_ADJ
1-4-3.
Adjusting Method
1.
Hall Adjustment
Perform this adjustment only when replacing the lens block. When
the microprocessor, circuit etc. is damaged, don't perform this adjust-
ment but check the operations only.
Adjustment Page
CE
Adjustment Address
54 to 57
1-1. Adjusting method when the lens is replaced:
Adjusting method:
Order Page Address
Data
Procedure
1
00
01
01
Set the data.
2
40
38
00
Set the data.
3
CE
54
Set the data. (Note)
4
CE
55
Set the data. (Note)
5
CE
56
Set the data. (Note)
6
CE
57
Set the data. (Note)
7
Save the data.
8
80
34
Check the data is “00”.
9
80
30
Check the data is “00”.
Note: The data of page: CE, address: 54 to 57, that are set in the
Orders 3 to 6 as described above, are shown on the data
sheet supplied with the replacement lens for repair.
Processing after Completing Adjustment:
Order Page Address
Data
Procedure
1
00
01
00
Set the data.
2
Check that the steady
shot operations have
been performed normally.
Fig. 6-1-18
Data for Page: CE, Address: 57
The right four digits of the seal (2-byte data)
Data for Page: CE, Address: 56
Y
 
XXXX
Data for Page: CE, Address: 55
The right four digits of the seal (2-byte data)
Data for Page: CE, Address: 54
P
 
XXXX
1-2. Adjusting method when replacement of lens is
not required and the SY-150 board is replaced:
When the data of page: CE, address: 54 to 57 can be
read from the defective SY-150 board before replace-
ment, and all of the data are not “00”:
Adjusting method:
Order Page Address
Data
Procedure
1
00
01
01
Set the data.
2
40
38
00
Set the data.
3
CE
54
Set the previous data
4
CE
55
Set the previous data
5
CE
56
Set the previous data
6
CE
57
Set the previous data
7
Save the data.
8
80
34
Check the data is “00”.
9
80
30
Check the data is “00”.
When the data of the page: CE, address: 54 to 57 can
be read out from the defective SY-150 board before
replacing it, and all of the data are “00”:
1) Replace the lens with the replacement lens and perform “1-1.
Adjusting method when the lens is replaced”.
When the data of page: CE, address: 54 to 57 cannot
be read from the defective SY-150 board:
1) Replace the lens with the replacement lens and perform “1-1.
Adjusting method when the lens is replaced”.
Page of 36
Display