DSC-H100, DSC-H200 (serv.man2) - Sony Digital Camera Service Manual (repair manual). Page 6

Read Sony DSC-H100 / DSC-H200 (serv.man2) Service Manual online

DSC-H100/H200_ADJ
5-6
Adjustment order
Screen display
5-3-5. WB/AGC Adjustment
The WB/AGC (White Balance/Analog Gain Control) Adjustment order 
is as follows.
Small pattern box (PTB-1450) setting: 
Color temperature = 3100 ± 200K
Luminance: LV12.2 ± 0.5
The adjustment is finished normally.
LimitR:312 579
LimitB:338 628
MEAN G
DayLig
R Gain
G Gain
B Gain
35376
3181
2561
7361
Time:13688
Move OK...
OK
Fig. 5-3-13
The adjustment is complete.
The adjustment is finished abnormally.
Limit:234 276
49 22, 191
ZPos :
WLuma:
LS:16-,
OC:
-42
OC :
Entry :
Gain :
AGC :
0x002e
0x0425
OK
NG
Cali Er
T
Fig. 5-3-14
Malfunction of WB/AGC  
adjustment result
5-3-6. MeShut26 Adjustment
The MeShut26 (Mechanical Shutter 26) Adjustment order is as follows.
Note:
Perform the MeShut26 Adjustment after those performed in 5-3-4 to 5-3-5.
Small pattern box (PTB-1450) setting: 
Color temperature = 3100 ± 200K
Luminance: LV12.2 ± 0.5
The adjustment is finished normally.
Iris No:
1
Time:574
OK
FINISH...
Fig. 5-3-16
The adjustment is complete.
Adjustment order
Screen display
Check that the camera is on the adjustment mode.
* For the setting procedure of the adjustment mode, refer to “5-1-5. Setting the Adjustment Mode” (Page 5-3).
Confirm the indication
on the screen.
In case of the adjustment is finished abnormally,
the following indication appears on the screen.
(Fig. 5-3-14)
In this case, confirm the adjusting environment
and readjust. 
Press the Control button “ b ” “ B ” and “ v ” “ V ” to change selected item. Choose “WB/AGC (LV10)”, 
press the Control button “ z ”, select “OK”, and press the Control button “ z ” to start.
* If the adjustment is disabled, refer to “5-1-6. Enabling the Adjustment” to enable the adjustment. (Page 5-3)
In case of the adjustment is finished normally, 
the adjustment completion indication appears 
on the screen. (Fig. 5-3-13)
Press the “      (Playback)” button to return to 
adjustment menu.
Press the Control button “ b ” “ B ” and “ v ” “ V ” to change selected item to “WB/AGC (LV10)”, 
and press the “       (Playback)” button. Press the Control button “ v ” “ V ” to change selected item 
to “Light Src”, and press the Control button “ b ” “ B ” to set the value as “00002”, and press the 
Control button “ z ”.
Place the camera in front of the Small pattern box (PTB-1450). (Fig. 5-3-12)
Finished normally.
Finished abnormally.
Confirm the indication
on the screen.
Finished abnormally.
Finished normally.
In case of the indication other than that shown in
Fig. 5-3-16 appears on the screen, confirm the
adjusting environment and readjust.
Press the Control button “ b ” “ B ” and “ v ” “ V ” to change selected item. Choose “MeShut26 (LV13)”, 
press the Control button “ z ”, select “OK”, and press the Control button “ z ” to start.
* If the adjustment is disabled, refer to “5-1-6. Enabling the Adjustment” to enable the adjustment. (Page 5-3)
In case of the adjustment is finished normally, 
the adjustment completion indication appears 
on the screen. (Fig. 5-3-16)
Press the “      (Playback)” button to return to 
adjustment menu.
Check that the camera is on the adjustment mode.
* For the setting procedure of the adjustment mode, refer to “5-1-5. Setting the Adjustment Mode” (Page 5-3).
Place the camera in front of the Small pattern box (PTB-1450). (Fig. 5-3-15)
Equipment required: Small pattern box (PTB-1450)
Cover camera lens and
Small pattern box (PTB-1450)
(All black)
Clear chart
Small pattern box
(PTB-1450)
5 mm or less
Black cloth
Camera
Fig. 5-3-12
Equipment required: Small pattern box (PTB-1450)
Cover camera lens and
Small pattern box (PTB-1450)
(All black)
Clear chart
Small pattern box
(PTB-1450)
5 mm or less
Black cloth
Camera
Fig. 5-3-15
Page of 11
Display

Click on the first or last page to see other DSC-H100 / DSC-H200 (serv.man2) service manuals if exist.