Read Sony DSC-H100 / DSC-H200 (serv.man2) Service Manual online
DSC-H100/H200_ADJ
5-4
5-3. CAMERA SECTION ADJUSTMENTS
5-3-1. Reading/Writing Lens data
Introduction:
- Please handle lens with care.
- Perform the operation additionally when replacing Main board or Lens.
- Read and record the lens data on the QR Code Label or Lens data Label attached to the lens. (Fig. 5-3-1)
- Please handle lens with care.
- Perform the operation additionally when replacing Main board or Lens.
- Read and record the lens data on the QR Code Label or Lens data Label attached to the lens. (Fig. 5-3-1)
- The 4-digit lens data attached to the DSC-H200 lens begins with 15 like 15XX.
01604750
(3 digits)
45
45
45
QR Code Label
QR Code Label
Lens data
DSC-H100 :
DSC-H200 :
Type A
Type A
Type B
80030802
50 35 50
80030802
50 35 50
Lens data
(Handwritten)
(Handwritten)
80383884
15301430
45 40 50
15301430
45 40 50
80383884
15301430
45 40 50
15301430
45 40 50
Lens data
(Fig.
5-3-1)
Preparations:
Put the folder “Wrirte_Lens Data” downloaded in “5-1-5. Setting the Adjustment Mode” (Page 5-3) in any place of the PC.
Confirm that includes the following items.
• Write_LensCode_v[][][].exe
• UI43Api.dll
• eepromtool.ini
• Write_LensCode_v[][][].exe
• UI43Api.dll
• eepromtool.ini
The USB Driver is sane as “5-3-13. Set Language Destination”.
Procedure:
The example are described in the case of DSC-H100.
1) Check that the camera is on the adjustment mode.
The example are described in the case of DSC-H100.
1) Check that the camera is on the adjustment mode.
Connect the camera and the PC.
2) Double click the “Write_LensCode_v[][][].exe” to start up the writing tool.
(Fig.
5-3-2)
Reading Lens data
3) Click “Read QRCode”.
4) The message “Read QRCode Finish !!” will be displayed. Lens data is displayed in the “QRCode” text field.
3) Click “Read QRCode”.
4) The message “Read QRCode Finish !!” will be displayed. Lens data is displayed in the “QRCode” text field.
(Fig.
5-3-3)
Writing Lens data
3) Enter the recorded lens data in the “QRCode” text field.
4) Click “Write QRCode.”
5) The message “Write QRCode Finish !!” will be displayed.
3) Enter the recorded lens data in the “QRCode” text field.
4) Click “Write QRCode.”
5) The message “Write QRCode Finish !!” will be displayed.
(Fig.
5-3-4)
5-3-2. Setting Default Gyro Value
Perform the this operation additionally when replacing Main board or Lens.
Preparations:
Put the folder “Set_Default Gyro Value” downloaded in “5-1-5. Setting the Adjustment Mode” (Page 5-3) in any place of the PC.
Confirm that includes the following items.
• Set_DefaultGyro_v[][][].exe
• UI43Api.dll
• Set_DefaultGyro_v[][][].exe
• UI43Api.dll
The USB Driver is sane as “5-3-13. Set Language Destination”.
Procedure:
The example are described in the case of DSC-H100.
1) Check that the camera is on the adjustment mode.
The example are described in the case of DSC-H100.
1) Check that the camera is on the adjustment mode.
Connect the camera and the PC.
2) Double click the “Set_DefaultGyro_v[][][].exe” to start up the writing tool. (Fig. 5-3-5)
3) Press the “Set Default ” button.
3) Press the “Set Default ” button.
(Fig.
5-3-5)
4) In case of the setting is finished normally, the setting completion indication appears on the screen. (Fig. 5-3-6)
The power of the camera turns off automatically.
(Fig.
5-3-6)
The changed portions from
Ver. 1.0 are shown in blue.
Ver. 1.0 are shown in blue.
Ver. 1.1 2013.05
Click on the first or last page to see other DSC-H100 / DSC-H200 (serv.man2) service manuals if exist.