DSC-H100, DSC-H200 (serv.man2) - Sony Digital Camera Service Manual (repair manual). Page 4

Read Sony DSC-H100 / DSC-H200 (serv.man2) Service Manual online

DSC-H100/H200_ADJ
5-4
5-3. CAMERA SECTION ADJUSTMENTS
5-3-1.   Reading/Writing Lens data
Introduction:
-  Please handle lens with care.
-  Perform the operation additionally when replacing Main board or Lens.
-  Read and record the lens data on the QR Code Label or Lens data Label attached to the lens. (Fig. 5-3-1)
-  The 4-digit lens data attached to the DSC-H200 lens begins with 15 like 15XX.
01604750
(3 digits)
45
45
45
QR Code Label
QR Code Label
Lens data
DSC-H100 :
DSC-H200 :
Type A
Type B
80030802
 50 35 50
80030802
 50 35 50
Lens data
(Handwritten)
80383884
15301430
 45 40 50
80383884
15301430
 45 40 50
Lens data
 (Fig. 
5-3-1)
Preparations:
 
Put the folder “Wrirte_Lens Data” downloaded in “5-1-5. Setting the Adjustment Mode” (Page 5-3) in any place of the PC.
 
Confirm that includes the following items.
• Write_LensCode_v[][][].exe
• UI43Api.dll
• eepromtool.ini
The USB Driver is sane as “5-3-13. Set Language Destination”.
Procedure:
The example are described in the case of DSC-H100.
1)  Check that the camera is on the adjustment mode.
 
Connect the camera and the PC.
2)   Double click the “Write_LensCode_v[][][].exe” to start up the writing tool.
 
 (Fig. 
5-3-2)
Reading Lens data
3)  Click “Read QRCode”.
4)  The message “Read QRCode Finish !!” will be displayed. Lens data is displayed in the “QRCode” text field.
 
 (Fig. 
5-3-3)
Writing Lens data
3)  Enter the recorded lens data in the “QRCode” text field.
4)  Click “Write QRCode.”
5)  The message “Write QRCode Finish !!” will be displayed.
 
 (Fig. 
5-3-4)
5-3-2. Setting Default Gyro Value
Perform the this operation additionally when replacing Main board or Lens.
Preparations: 
 
Put the folder “Set_Default Gyro Value” downloaded in “5-1-5. Setting the Adjustment Mode” (Page 5-3) in any place of the PC.
 
Confirm that includes the following items.
• Set_DefaultGyro_v[][][].exe
• UI43Api.dll
The USB Driver is sane as “5-3-13. Set Language Destination”. 
Procedure:
The example are described in the case of DSC-H100.
1)  Check that the camera is on the adjustment mode.
 
Connect the camera and the PC. 
2)  Double click the “Set_DefaultGyro_v[][][].exe” to start up the writing tool. (Fig. 5-3-5)
3)  Press the “Set Default ” button. 
 
 (Fig. 
5-3-5)
4)  In case of the setting is finished normally, the setting completion indication appears on the screen. (Fig. 5-3-6)
 
The power of the camera turns off automatically.
 
 (Fig. 
5-3-6)
The changed portions from
Ver. 1.0 are shown in blue.
Ver. 1.1 2013.05
Page of 11