TCM-900DV - Sony Audio Service Manual (repair manual). Page 6

Read Sony TCM-900DV Service Manual online

TCM-900DV
6
3-2. ELECTRICAL ADJUSTMENTS
• Standard Level
Input signal level
MIC
– 60dBs
Output signal level
EAR (EARPHONE)
1.6k
Ω, –22,4dBs
• Test Tape
Type
Signal
Used for
WS-48A
3kHz, 0dB
           tape speed adjustment
   0dB=0.775V
Setting :
VOL Control (RV301)
: mechanical mid
REC TIME (S903)
: normal(4.8cm/s)
SPEED CONTROL (RV901): normal (center click)
DPC(MANUAL) Adjustment
Setting :
DPC(S904) switch
: MANUAL
Tape speed
: 4.8cm/s
Mode
: PLAY
Procedure :
[MAIN BOARD](SIDE B)
1. Connect the freguency counter to TP47 and TP8(GND).
2. Adjust RV401 so that the freguency at TP47 becomes 220 Hz.
Standard value : 117 to 223 Hz
Adjustment Location : Main board (See page 7)
SECTION 3
ADJUSTMENTS
3-1. MECHANICAL ADJUSTMENTS
PRECAUTION
1. Clean the following parts with a denatured alcohol-moistened
swab  :
record/playback/erase head
pinch roller
rubber belts
capstan
2. Demagnetize the record/playback head with a head demagne-
tizer. (Do not bring the head demagnetizer close to the erase
head.)
3. Do not use a magnetized screwdriver for the adjustments.
4. After the adjustments, apply suitable locking compound to the
parts adjusted.
5. The adjustments should be performed with the rated power sup-
ply voltage unless otherwise noted.
6. Power supply voltage : 3V DC.
Torque Measurement
Mode
Torque Meter
Meter Reading
Forward
CQ-102C
1.97 to 3.92 mN • m
(20 to 40 g • cm)
(0.28 to 0.55 oz• inch)
Forward
CQ-102C
0.05 to 0.49 mN • m
(0.5 to 5.0 g • cm)
(0.007 to 0.07 oz• inch)
Fast Forward
more than 4.90 mN • m
and Rewind
CQ-201B
(50 g • cm)
(0.7 oz• inch)
Tape Tension  Measurement
Mode
Tension Meter
Meter Reading
Forward
CQ-403A
more than 50g
( 1.77oz)
/Reverse
1
36
25
48
35
15
40
12
30
24
20
37
45
5
10
13
L401
IC401
R409
C420
C422
R417
R416
C416
R405
R402
R406
R407
RV401
C401
304
8
C410
C402
C403
C414
C415
R403
R404
R401
C412
C413
C407
TP46
TP82
TP47
TP51
TP63
+
frequency counter
TP47
TP8(GND)
Note: Adjust before the tape speed adjustment
Page of 32
Display

Click on the first or last page to see other TCM-900DV service manuals if exist.