TC-WE675 - Sony Audio Service Manual (repair manual). Page 8

Read Sony TC-WE675 Service Manual online

8
TC-WE675
PRECAUTION
1. Clean the following parts with a denatured alcohol-moistened
swab :
record/playback/erase head
pinch roller
rubber belts
capstan
idlers
2. Demagnetize the record/playback head with a head demagne-
tizer.
3. Do not use a magnetized screwdriver for the adjustment.
4. After the adjustments, apply suitable locking compound to the
parts adjusted.
5. The adjustments should be performed with the rated power sup-
ply voltage unless otherwise noted.
Torque Measurement
SECTION 5
ELECTRICAL ADJUSTMENTS
SECTION 4
MECHANICAL ADJUSTMENTS
PRECAUTION
1. The adjustment should be performed in the publication.
(Be sure to male playback adjustment at first.)
2. The adjustments and measurement should be performed for both
L-CH and R-CH.
• Switch position
DOLBY NR switch
: OFF
DIRECTION MODE switch : g
• Standard record position :
Deliver the standard input signal level to input jack and set the
REC LEVEL  knob to obtain the standard output signal level
as follows.
– Record Mode–
 0 dBs = 0.775 V
Standard Input Level
Test Mode
1. While pressing the  H/FRONT (DECK A)  and  REC MUT-
ING W   buttons with the power off, press the  !  button to turn
on the power. The fluorescent display tube lights up for about
one second, and the test mode is set. The test mode performs the
following two special functions.
• Playback speed switching function
Pressing the  HIGH/NORMAL  button switches the playback
speed between standard/double speed.
• Counter RESET & MEMORY function
Resets the counter when recording starts. When rewound with
the  m (AMS)  button after recording, stops at the point where
recording started.
2. To release the test mode, turn OFF the power switch.
Mode
Torque meter
Meter reading
Forward
CQ-102C
30 to 65 g • cm
(0.42 to 0.90 oz • inch)
Forward
back
tension
CQ-102C
DECK A : 1 to 6 g • cm
(0.014 to 0.083 oz • inch)
DECK B : 2 to 9 g • cm
(0.028 to 0.125 oz • inch)
Reverse
CQ-102RC
30 to 65 g • cm
(0.42 to 0.90 oz • inch)
Reverse
back
tension
CQ-102RC
1 to 6 g • cm
(0.014 to 0.083 oz • inch)
FF/REW
CQ-201B
70 to 120 g • cm
(0.97 to 1.67 oz • inch)
set
+
AF OSC
attenuator
10 k
600 
LINE IN
level meter
LINE OUT
47 k
Standard Output Level
Test Tape
Input terminal
LINE IN
source impedance
10 k
input signal level
0.5 V (–3.8 dBs)
Input terminal
LINE IN
source impedance
10 k
input signal level
0.5 V (–3.8 dBs)
Tape
Contents
Use
P-4-A100
10 kHz, –10 dB
Azimuth Adjustment
WS-48B
3 kHz, 0 dB
Tape Speed Adjustment
P-4-L300
315 Hz, 0 dB
PB Level Adjustment
Page of 47
Display

Click on the first or last page to see other TC-WE675 service manuals if exist.