TC-WE675 - Sony Audio Service Manual (repair manual). Page 9

Read Sony TC-WE675 Service Manual online

9
TC-WE675
Record/Playback Head Azimuth Adjustment
DECK A    DECK B
Procedure:
1. Forward Playback Mode
2. Turn the adjustment screw for the maximum output levels. If
these levels do not match, turn the adjustment screw until both
of output levels match together within 1 dB.
3. Playback Mode
4. Change the reverse playback mode and repeat the steps 1 to 3.
5. After the adjustment, lock the adjustment screws with suitable
locking compound.
Adjustment Location: – record/playback head –
Tape speed Adjustment     DECK A    DECK B
Adjust DECK A first
Procedure:
– Forward Playback Mode –
(High speed adjustment)
1. Press the  PITCH CONTROL  button to set to  OFF .
2. Set to test mode. (Refer to page 11.)
3. Press the  H  button to playback.
4. Press the  HIGH/NORMAL  button to playback at double speed.
5. Adjust RV316 (DECK A), RV416 (DECK B) so that the fre-
quency counter reading becomes 5,980 ± 80 Hz.
(Normal speed adjustment)
6. Press the  H  button to playback.
7. Press the  HIGH/NORMAL  button to playback at normal speed.
8. Adjust RV317 (DECK A), RV417 (DECK B) so that the fre-
quency counter reading becomes 3,000 ± 90 Hz.
(Pitch control adjustment) (DECK A)
9. Press the  PITCH CONTROL  button to set to  ON .
10. Set  PITCH CONTROL  knob to mechanical center.
11. Press the  H  button to playback.
12. Adjust RV318 so that the frequency counter reading becomes
2,990 ± 90 Hz.
Adjustment Location: MAIN board (See page 14.)
Sample value of wow and flutter
W.RMS (JIS) less than 0.3% .
(test tape : WS-48B)
Playback Level Adjustment     DECK A    DECK B
Procedure:
– Forward Playback Mode –
Adjust DECK A : RV111 (L-CH), RV211 (R-CH) and
DECK B : RV121 (L-CH), RV221 (R-CH) so the level meter read-
ing becomes the adjustment limits below.
Adjustment Value:
LINE OUT level : –7.7 dBs ± 0.5 dB (0.301 to 0.338 V)
Level difference between channels : within 0.5 dB
Confirm that the LINE OUT level does not change in playback mode
while changing the mode from playback to stop several times.
Adjustment Location: MAIN board (See page 14.)
set
test tape
P-4-A100
(10 kHz, –10 dB)
level meter
LINE OUT
47 k
within
1 dB
within
1 dB
output
level
R-CH
peak
R-CH
peak
L-CH
peak
L-CH
peak
screw
position
screw position
V
H
Screen Pattern
set
In phase
45˚
90˚
135˚
180˚
good
wrong
47 k
47 k
L-CH
R-CH
test tape
P-4-A100
(10 kHz, –10 dB)
LINE OUT
oscilloscope
forward side
reverse side
adjustment screws
set
frequency counter
47 k
LINE OUT
test tape
WS-48B
(3 kHz, 0 dB)
set
test tape
P-4-L300
(315 Hz, 0 dB)
level meter
LINE OUT
47 k
Page of 47
Display