STR-KIV300 - Sony Audio Service Manual (repair manual). Page 63

Read Sony STR-KIV300 Service Manual online

STR-KIV300
63
Pin No.
Pin Name
I/O
Description
N7
A12
I
Address inputs: Provided the row address for active commands and the column address 
for Read/Write commands to select one location out of the memory array in the respective 
bank. The address inputs also provide the op-code during Mode Register Set commands.
Burst Chop: A12 is sampled during Read and Write commands to determine if burst chop (on-
the-fl y) will be performed. (HIGH: no burst chop, LOW: burst chopped).
N8
BA1
I
Bank Adress Inputs: BA1 defi ne to which bank an Active, Read, Write or Precharge command 
is being applied. Bank address also determines if the mode register or extended mode register 
is to be accessed during a MRS cycle.
N9
VDD
-
Power Supply: 1.5V +/-0.075
P1
VSS
-
Ground
P2
A5
I
Address inputs: Provided the row address for active commands and the column address for 
Read/Write commands to select one location out of the memory array in the respective bank. 
The address inputs also provide the op-code during Mode Register Set commands.
P3
A2
I
Address inputs: Provided the row address for active commands and the column address for 
Read/Write commands to select one location out of the memory array in the respective bank. 
The address inputs also provide the op-code during Mode Register Set commands.
P4
NO_USE
-
Not used
P5
NO_USE
-
Not used
P6
NO_USE
-
Not used
P7
A1
I
Address inputs: Provided the row address for active commands and the column address for 
Read/Write commands to select one location out of the memory array in the respective bank. 
The address inputs also provide the op-code during Mode Register Set commands.
P8
A4
I
Address inputs: Provided the row address for active commands and the column address for 
Read/Write commands to select one location out of the memory array in the respective bank. 
The address inputs also provide the op-code during Mode Register Set commands.
P9
VSS
-
Ground
R1
VDD
-
Power Supply: 1.5V +/-0.075
R2
A7
I
Address inputs: Provided the row address for active commands and the column address for 
Read/Write commands to select one location out of the memory array in the respective bank. 
The address inputs also provide the op-code during Mode Register Set commands.
R3
A9
I
Address inputs: Provided the row address for active commands and the column address for 
Read/Write commands to select one location out of the memory array in the respective bank. 
The address inputs also provide the op-code during Mode Register Set commands.
R4
NO_USE
-
Not used
R5
NO_USE
-
Not used
R6
NO_USE
-
Not used
R7
A11
I
Address inputs: Provided the row address for active commands and the column address for 
Read/Write commands to select one location out of the memory array in the respective bank. 
The address inputs also provide the op-code during Mode Register Set commands.
R8
A6
I
Address inputs: Provided the row address for active commands and the column address for 
Read/Write commands to select one location out of the memory array in the respective bank. 
The address inputs also provide the op-code during Mode Register Set commands.
R9
VDD
-
Power Supply: 1.5V +/-0.075
T1
VSS
-
Ground
T2
RESET
I
Active Low Asynchronous Reset: Reset is active when RESET is LOW, and inactive when 
RESET is HIGH. RESET must be HIGH during normal operation. RESET is CMOS rail to rail 
signal with DC high and low at 80% and 20% of VDD, example, 1.20V for DC high and 0.30V 
for DC low.
T3
A13
I
Address inputs: Provided the row address for active commands and the column address for 
Read/Write commands to select one location out of the memory array in the respective bank. 
The address inputs also provide the op-code during Mode Register Set commands.
T4
NO_USE
-
Not used
T5
NO_USE
-
Not used
T6
NO_USE
-
Not used
T7
A14
I
Address inputs: Provided the row address for active commands and the column address for 
Read/Write commands to select one location out of the memory array in the respective bank. 
The address inputs also provide the op-code during Mode Register Set commands.