STR-DA5600ES - Sony Audio Service Manual (repair manual). Page 9

Read Sony STR-DA5600ES Service Manual online

STR-DA5600ES
9
MAIN  BOARD  SERVICE  POSITION
MAIN board
insulating sheet
CONTROL board
CAPACITOR  ELECTRICAL  DISCHARGE  PROCESSING
When checking the board, the electrical discharge is necessary for the electric shock prevention.
Connect the resistors referring to the fi gure below.
•  MAIN board (C2490, C2491)
 
Both ends of respective capacitors.
800 
:/2 W
800 
:/2 W
– MAIN Board (Conductor Side) –
C2490 C2491