13
6. Press the H button.
7. Check that the waveform on oscilloscope is clear, and the level
7. Check that the waveform on oscilloscope is clear, and the level
and jitter of waveform satisfy the specifications.
8. After checking, press the
x
button.
9. Repeat steps 3 through 8 for respective discs.
10. Press the
10. Press the
!
button to turn the power off.
Specified Value:
Disc
A
Jitter (displayed value)
SATD-S2
1.25 to 1.65 Vp-p
20 (Hex) or less
TCD-784
1.3 to 1.7 Vp-p
15 (Hex) or less
bbb
CD1
Discchk
XX
XX
Disc type (refer to Disc check list (page 11))
6. Press the - button and 1 button, the - button and 2 but-
ton, and the - button and 3 button on the remote commander
successively to execute the focus search.
successively to execute the focus search.
7. Check that the waveform on oscilloscope is within the level
A and B specifications.
8. After checking, press the
x
button.
9. Repeat steps 3 through 8 for respective discs.
10. Press the ! button to turn the power off.
10. Press the ! button to turn the power off.
Specified Value:
Disc
A
B
SATD-S2
1.5 to 2.3Vp-p
- 0.1 to +0.1V
TCD-784
S Curve Check
Connection:
RF Level Check
Connection:
MAIN board
TP524 (FE)
TP501 (VC)
+
–
–
oscilloscope
(normal mode)
Procedure:
1. Connect an oscilloscope to the TP524(FE) and TP501(VC) on
1. Connect an oscilloscope to the TP524(FE) and TP501(VC) on
the MAIN board.
2. Set the Adjustment-1 Mode. (See 5-2. Adjustment-1 Mode in
SECTION 5 (page 11))
3. Set a disc (SATD-S2 or TCD-784).
4. Press the 3 button and - button on the remote commander
4. Press the 3 button and - button on the remote commander
to make the disc type checked.
Note:
If the disc check was made in the Adjustment-1 Mode, pressing
another button immediately after pressing the 3 and - buttons
on the remote commander could cause the microcomputer to run
out of control, thus requiring extreme care.
another button immediately after pressing the 3 and - buttons
on the remote commander could cause the microcomputer to run
out of control, thus requiring extreme care.
5. Confirm that the disc was checked.
A
B
S curve waveform
VC
MAIN board
TP503 (RF)
TP501 (VC)
+
–
–
oscilloscope
(auto mode)
(auto mode)
Procedure:
1. Connect an oscilloscope to the TP503(RF) and TP501(VC) on
1. Connect an oscilloscope to the TP503(RF) and TP501(VC) on
the MAIN board.
2. Set the Adjustment-1 Mode. (See 5-2. Adjustment-1 Mode in
SECTION 5 (page 11))
3. Set a disc (SATD-S2 or TCD-784).
4. Press the 3 button and - button on the remote commander
4. Press the 3 button and - button on the remote commander
to make the disc type checked.
Note:
If the disc check was made in the Adjustment-1 Mode, pressing
another button immediately after pressing the 3 and - buttons
on the remote commander could cause the microcomputer to run
out of control, thus requiring extreme care.
another button immediately after pressing the 3 and - buttons
on the remote commander could cause the microcomputer to run
out of control, thus requiring extreme care.
5. Confirm that the disc was checked.
VOLT/DIV: 200 mV
TIME/DIV: 500 ns
TIME/DIV: 500 ns
RF signal waveform
A
bbb
CD1
+ 00
00
~00
09
Jitter value
(HEX)
(HEX)
not fixed
Adjustment Location : See page16.
Adjustment Location : See page16.
bbb
CD1
Discchk
XX
XX
Disc type (refer to Disc check list (page 11))
Note:
For easier observation of this waveform, extend the sweep time
and raise the brightness.
Note:
Clear RF waveform refers to the waveform where
◊
shapes should
be distinctively observed in the center.
Display example: