NW-ZX100, NW-ZX100HN - Sony Audio Service Manual (repair manual). Page 7

Read Sony NW-ZX100 / NW-ZX100HN Service Manual online

NW-ZX100/ZX100HN
7
7.  The following message is displayed. Then, the initial setting 
operation starts.
Firmware update will start.
Copying the new firmware image [NW_WM_FW.UPG]...
 Copying NW_WM_FW.UPG...
    1 file(s) copied.
Ready to start fupdate SCSI command !
execscsitest f: “0xfc 0 0x04 0x64 0x62 0x6d 0x6e 0 0 0 0 0”
Firmware update has started.
The firmware update tool will close.
(Using 2-byte characters, it may not be displayed correctly)
C:\NOCOLOR>_
8.  The “WALKMAN” reboots automatically after the initial set-
ting is completed. After rebooting, the updating is success 
when USB connection screen is displayed on the liquid crystal 
display of the “WALKMAN”.
  After rebooting, check that USB connection screen is dis-
played on the liquid crystal display of the “WALKMAN”.
9.  Input “exit” and press the Enter key on PC to close the com-
mand prompt application software.
C:\NOCOLOR>exit
2-3.  
Confi rm settings
Be sure to that the correct destination and the initial settings have 
been perform.
Used tool:
Determination_HP_NWZX100_yyyymmdd.zip
Procedure:
1.  Connect “WALKMAN” to PC.
 
(The power supply of “WALKMAN” is automatically turned 
on)
2.  Open the my computer window on PC, and confi rm  how 
“WALKMAN” is recognized on PC.
 
(In the following example, “WALKMAN” is recognized by 
MSC connection)
 
The check of the drive letter is necessary.
 
(At this example, it is “F”)
3. From in the “Determination_HP_NWZX100_yyyymmdd” 
folder, copy the folder of “dest_hp” to root directory of C drive 
on PC.
4.  Start the command prompt application software, and move to 
the folder in which the destination and supplied headphones 
identifi cation tool.
 
(In this example, “cd c:\dest_hp” is inputted)
C:\Users\XXXXX>cd c:\dest_hp
C:\dest_hp>
5.  Input the following command according to the information 
checked at step 2, and press the Enter key on PC.
 “dest_hp.bat 
f:”
 
(“f:” is drive letter)
C:\dest_hp>dest_hp.bat f:
6.  It will appear the following results.
 Confi rm the Destination code and Headphones code.
C:\dest_hp>dest_hp.bat f:
C:\dest_hp>del dest_hp.dat
C:\dest_hp>execscsitest f: "0xFC 0 0x44 0x64 0x68 0x70 0 0 0 0 0 0" /i dest_hp.d
at 8
C:\dest_hp>dump dest_hp.dat
03 01 00 00 43 4e 52 48 ff                         ....CNRH.
C:\dest_hp>_
Destination code
Headphones code
Model
Destination
Destination
code
Headphones
code
NW-ZX100HN
AEP, UK
03 01 00 00
CNRH
NW-ZX100HN
EE
02 00 00 00
CNRH
NW-ZX100
E, AUS, JE
06 00 00 00
PHON
NW-ZX100
CH
04 00 00 00
PHON
Headphones code (supplied headphones):
PHON: Not supplied
CNRH:  MDR-NW750NE (AEP, UK), MDR-NW750N (EE)
7.  Input “exit” and press the Enter key on PC to close the com-
mand prompt application software.
C:\dest_hp>exit
Page of 42
Display

Click on the first or last page to see other NW-ZX100 / NW-ZX100HN service manuals if exist.