1-3. 3.3V/2.4V Generator Circuit 
 
Fig.1-2 shows the 3.3V/2.4V generator circuit. 
 
= 3.3V voltage = 
The capacitor C9011 which is connected to Pin-33 of Power Control IC9003 is mounted for adjusting the output timing of Pin-34 of IC9003. This signal line becomes “H” in the 
wake-up mode and “L” in the sleep mode. In this unit, this signal controls ON and OFF of 3.3V DC-DC CONVERTER IC9004. 
When  IC9003  is  in  the  wake-up  mode,  CRST2  signal  line  becomes  “H”.  By  this  “H”  signal,  Q9009  turns  “OFF”  and  “L”  signal  is  input  to  Pin-1  [SHDN]  of  3.3V  DC-DC 
CONVERTER IC9004. Then, IC9004 starts-up. When IC9004 starts up, IC9004 outputs the switching waveform from Pin-4 [SW]. Then, 3.3[V] is generated by the DC-DC 
converter circuit composed of IC9004, L9003 and C9005. Then, the created voltage is supplied as the following 3 kinds of voltage. 
 
3.3V voltage 
 
3.3V_A voltage 
 
3.3V_HDD voltage 
 
= Mode Control of 3.3V DC-DC CONVERTER IC9004 = 
3.3V DC-DC CONVERTER IC9004 has the lower power consumption mode and this mode is controlled by the signal output from pin-157[XHDD_PWR_CTL] of MULTI 
INTERFACE IC7001. IC7001 outputs “H” signal when it recognizes that the following condition is satisfied. 
 
= Condition that IC9004 enters the lower power consumption mode = 
  HDD drive is “OFF” 
 
Table.1-8 Mode control of 3.3V DC-DC CONVERTER IC9004 
IC7001 Pin-157 [XHDD_PWR_CTL] 
Lower Power Consumption Mode 
OFF 
ON 
 
= 2.4V voltage = 
When 3.3V_A voltage is supplied, it is input to pin-4[VDD] and pin-1[CE] of +2.4V REGULATOR IC4302. Then IC4302 starts up. IC4302 generates +2.4[V] and outputs it from 