NW-HD5 (serv.man2) - Sony Audio Service Manual (repair manual). Page 4

Read Sony NW-HD5 (serv.man2) Service Manual online

Copying is strictly prohibited 
 
1. MAIN SYSTEM CONTROLLER IC1003 
When  MAIN  SYSTEM  CONTROLLER IC1003  starts  up, it  outputs “H”  signal  from Pin-147[PQ1/FFCLR].  By  this “H”  signal, the  switch  inside  IC1001  is turned  “ON”. Then 
XDCIN_DET signal is input to Pin-150 [PQ4] of MAIN SYSTEM CONTROLLER IC1003. IC1003 detects whether the driving voltage is the battery voltage or DC-IN 6V voltage 
supplied from AC power adapter by using the input voltage shown in Table.1-2. 
 
Table.1-2 Detecting DC-IN 6V voltage 
IC1003 Pin-150 [PQ4] 
Description 
DC-IN 6V voltage is supplied. 
DC-IN 6V voltage is not supplied. 
 
2. System Controller Circuit inside IC9003 
When any of the input signals to pin-2 [XWK4] through pin-5 [XWK1] of Power Control IC9003 changes from “H” to “L”, the system controller section inside IC9003 wakes up.   
 
The “wake-up conditions” of the unit is shown in Table 1-3. 
 
Table.1-3 Wake-up conditions 
 
Pin-5 [XWK1] of IC9003 
Pin-4 [XWK2] of IC9003 
Pin-3 [XWK3] of IC9003 
Pin-2 [XWK4] of IC9003 
Condition 
When any key of the remote controller is 
pressed 
When any key of the unit is 
pressed 
When VBUS voltage is supplied 
to the unit. (Refer to Fig.1-1) 
When DC-IN 6V voltage is 
supplied to the unit from AC 
power adapter.   
(Refer to Fig.1-1) 
 
3. MAIN SYSTEM CONTROLLER IC1003 
MAIN SYSTEM CONTROLLER IC1003 detects whether the battery is inserted or not by using the input status shown in Table.1-4. 
 
Table.1-4 Battery Detection 
IC1003 Pin-118 [PD0] 
Description 
Battery is inserted. 
Battery is not inserted. 
 