NW-HD5 (serv.man2) - Sony Audio Service Manual (repair manual). Page 12

Read Sony NW-HD5 (serv.man2) Service Manual online

Copying is strictly prohibited 
12 
 
 
CHARGE CONTROL IC9002 outputs status signals shown in Table.2-4 while charging to MAIN SYSTEM CONTROLLER IC1003. 
 
Table.2-4 Status signal 
IC9002 Pin-2 [XSTAT1] 
IC9002 Pin-3 [XSTAT2] 
Status 
When pre-charging 
Open 
When normal-charging 
Open 
When the charging operation terminates 
Open 
Open 
Error Status 
 
Battery is not connected 
 
Detecting the abnormal temperature 
 
Detecting the timer fault 
Etc. 
 
Table.2-5 Monitoring the charging operation by MAIN SYSTEM CONTROLLER IC1003 
IC1003 Pin-148 [PQ2] 
IC1003 Pin-149 [PQ3] 
Status 
When pre-charging 
When normal-charging 
When the charging operation terminates 
Error Status 
 
Battery is not connected 
 
Detecting the abnormal temperature 
 
Detecting the timer fault 
Etc. 
 
 
Table.2-6 Charging Current 
Power Source 
Pre-charging 
(Until BATT voltage becomes 3[V]) 
Constant-Current Charging 
Remark 
AC Power Adapter 
Approx. 50mA 
Approx. 400mA 
USB (500mA – Permit) 
Approx. 50mA 
Approx. 220mA 
Varies depending on conditions. The left 
values are when connecting with PC 
without transferring data 
USB (100mA – Permit) 
Approx. 50mA 
Approx. 90mA 
Varies depending on conditions. The left 
values are while LowBATT and no PC 
connecting screen appearing 
 
Note: 
 
The actual charging current of USB charge varies depending on the system conditions. It will be as follows.   
[Each VBUS limit current] – [Current consumed by the system] = [Actual charging current] 
 
When both AC adaptor and USB cable are inserted into the unit, charging current of the constant-current charging will be approx. 200mA, about half in the 
case of AC adaptor alone. 
 
Page of 16