8. Press the 
 Bx 
 key, monochrome lattice is displayed on the LCD
of main unit.
9. Press the [MENU] key to display minor item, and press the  M
m   key to select the “LCD 4”.
10. Press the 
 Bx 
 key, monochrome lattice (reverse version of step
8) is displayed on the LCD of main unit.
11. Press the [MENU] key, return to minor item selection screen.
5-3-6. G-sensor adjustment
X/Y/Z-axis direction is adjusted.
Adjustment method:
1. Enter the test mode.
2. Press the 
 , 
 key to display major item, and press the  M   m
key to select the “OTHERS”.
3. Press the 
 , 
 key to display minor item, and press the  M   m
key to select the “G CLB”.
4. Press the 
 Bx 
 key, “+X” is displayed. Main unit is fixed so that
1
 of fig.1 may become downward and press the 
 Bx 
 key.
5. “–X” is displayed. Main unit is fixed so that 2 of fig.1 may
become downward and press the 
 Bx 
 key.
6. “+Y” is displayed. Main unit is fixed so that 3 of fig.1 may
become downward and press the 
 Bx 
 key.
7. “–Y” is displayed. Main unit is fixed so that 4 of fig.1 may
become downward and press the 
 Bx 
 key.
8. “+Z” is displayed. Main unit is fixed so that 5 of fig.1 may
become downward and press the 
 Bx 
 key.
9. “–Z” is displayed. Main unit is fixed so that 6 of fig.1 may
become downward and press the 
 Bx 
 key.
10. “CALIB” is displayed. Press the 
 Bx 
 key, G-sensor is adjusted.
Then “FIN”, “DAT NG” or “SEN NG” is displayed automatically.
FIN
: adjusted normally.
DAT NG : The data for performing a calibration is faulty.
SEN NG : The value acquired from the G-sensor is faulty.
11. Press the [MENU] key, return to minor item selection screen.
5-3-7. G-sensor adjustment check
This mode checks that G-sensor adjustment is performed or not
performed.
Checking method:
1. Enter the test mode.
2. Press the 
 , 
 key to display major item, and press the  M   m
key to select the “OTHERS”.
3. Press the 
 , 
 key to display minor item, and press the  M   m
key to select the “G CHK”.
4. Press the 
 Bx 
 key, “START” is displayed. Then “OK” or “YET”
is displayed automatically.
5. Press the [MENU] key, return to minor item selection screen.
Fig.1   Axis direction of G-sensor adjustment
4
2
5
3
1
6
    OTHERS
LCD display
    G CHK
LCD display
    START
LCD display
    OK
r
Page of 52