NW-HD3 (serv.man2) - Sony Audio Service Manual (repair manual). Page 8

Read Sony NW-HD3 (serv.man2) Service Manual online

Copying is strictly prohibited 
 
During the charging operation, CHARGE CONTROL IC9501 outputs the status signals shown in Table.3-2 to MAIN SYSTEM CONTROLLER IC1003. And also, the status 
signal from pin-3[STAT1] of IC9501 is used for the ON/OFF control signal of the diode (Charging LED) inside the USB Adaptor. 
 
Table.3-2 Status signal 
IC9501 Pin-3 [STAT1] 
IC9501 Pin-4 [STAT2] 
Status 
Open 
Open 
Error Status 
 
Battery is not connected 
 
Detecting the abnormal temperature 
 
Detecting the timer fault 
Etc. 
Open 
When charging 
Open 
When the charging operation terminates 
 
Table.3-3 Monitoring the charging operation by MAIN SYSTEM CONTROLLER IC1003 
IC1003 Pin-148 [PQ2] 
IC1003 Pin-149 [PQ3] 
Status 
Error Status 
 
Battery is not connected 
 
Detecting the abnormal temperature 
 
Detecting the timer fault 
Etc. 
When charging 
When the charging operation terminates 
 