MDS-MX101 - Sony Audio Service Manual (repair manual). Page 16

Read Sony MDS-MX101 Service Manual online

– 16 –
5-8.
FOCUS  BIAS  ADJUSTMENT
Adjusting Method:
1. Load a continuously recorded disc (Refer to “5-4. Creating
MO Continuously Recorded Disc”.).
2. Press the
= 0 button or ) + button and display
“CPLAY MODE”.
3. Press the YES button and display “CPLAY MID”.
4. Press the EDIT/NO button when “C1= 
 AD=   ” is dis-
played.
5. Press the
= 0 button or ) + button and display
“FBIAS ADJUST”.
6. Press the YES button and display “
/
  a= ”.
The first four digits indicate the C1 error rate, the two digits
after [/] indicate ADER, and the 2 digits after [a=] indicate the
focus bias value.
7. Press the
) + button and find the focus bias value at
which the C1 error rate becomes 220. (Refer to note 2.)
8. Press the  YES  button and display “
/
  b=
”.
9. Press the
= 0 button and find the focus bias value at
which the C1 error rate becomes 220.  (Refer to note 2.)
10. Press the  YES button and display “
/
  c=
”.
11. Check that the C1 error rate is below 50 and ADER is 00.
Then press the YES button.
12. If the “(
)” in “
-
-
 ( )” is above 20, press the YES
button.
If below 20, press the EDIT/NO button and repeat the ad-
justment from step 2 again.
13. Press the EDIT/NO button and press the  
6  button to re-
move the continuously recorded disc.
Note 1: The relation between the C1 error and focus bias is as
shown in the following figure.  Find points a and b in the
following figure using the above adjustment.  The focal
point position c is automatically calculated from points a
and b.
Note 2: As the C1 error rate changes, perform the adjustment us-
ing the average vale.
5-9.
ERROR  RATE  CHECK
5-9-1.
CD Error Rate Check
Checking Method:
1. Load a test disc TDYS-1.
2. Press the
= 0 button or ) + button and display
“CPLAY MODE”.
3.  Press the YES button and display “CPLAY MID”.
4. “C1= 
  AD= 
” is displayed.
5. Check that the C1 error is below 20.
6. Press the EDIT/NO button, stop playback, press the
6  but-
ton, and remove the test disc.
5-9-2.
MO Error Rate Check
Checking Method:
1. Load a continuously recorded disc (Refer to “5-4. Creating
MO Continuously Recorded Disc”.).
2. Press the
= 0 button or ) + button and display
“CPLAY MODE”.
3. Press the  YES  button and display “CPLAY MID”.
4. “C1=
  AD=
” is displayed.
5. If the C1 error is below 50, check that ADER is 00.
6. Press the EDIT/NO button, stop playback, press
the
6 button, and remove the continuously recorded disc.
5-10. FOCUS  BIAS  CHECK
Change the focus bias and check the focus tolerance amount.
Checking Method:
1. Load a continuously recorded disc (Refer to “5-4. Creating
MO Continuously Recorded Disc”.).
2. Press the
= 0 button or ) + button and display
“CPLAY MODE”.
3. Press the YES button and display “CPLAY MID”.
4. Press the EDIT/NO button when “C1=
  AD=
” is dis-
played.
5. Press the
= 0 button or ) + button and display
“FBIAS CHECK”.
6. Press the YES button and display “
/
 c=
”.
The first four digits indicate the C1 error rate, the two digits
after [/] indicate ADER, and the 2 digits after [c=] indicate the
focus bias value.
Check that the C1 error is below 50 and ADER is 00.
7. Press the YES  button and display “
/
 b=
”.
Check that the C1 error is not below 220 and ADER is not
above 00 every time.
8. Press the YES button and display “
/
 a=
 ”.
Check that the C1 error is not below 220 and ADER is not
above 00 every time.
9. Press the EDIT/NO button, next press the
6 button, and re-
move the continuously recorded disc.
Note 1: If the C1 error and ADER are above 00 at points a or b,
the focus bias adjustment may not have been carried out
properly.  Adjust perform the beginning again.
C1 error
220
b
c
a
Focus bias value
(F. BIAS)
Page of 46
Display

Click on the first or last page to see other MDS-MX101 service manuals if exist.