Read Panasonic DMC-LC20PP / DMC-LC20PM / DMC-LC20E / DMC-LC20B / DMC-LC20A / DMC-LC20EN / DMC-LC20KR (serv.man2) Service Manual online

 2002      
DMC-LC20PP
DMC-LC20PM
DMC-LC20E
DMC-LC20B
DMC-LC20A
DMC-LC20EN
DMC-LC20KR
Vol. 2
Colour
(S)...........Silver Type
(K)...........Black Type (Except DMC-LC20PM/A/KR)
Digital Camera
ORDER NO. VMD0204017C0
B0
 1 
INTRODUCTION 
3
 1.1. 
INTRODUCTION 
3
 1.2. 
HOW TO DEFINE THE MODEL SUFFIX (NTSC or PAL
model) 
3
 2 
SAFETY PRECAUTIONS 
4
 2.1. 
GENERAL GUIDELINES 
4
 2.2. 
LEAKAGE CURRENT COLD CHECK 
4
 2.3. 
LEAKAGE CURRENT HOT CHECK (See Figure 1.) 
4
 3 
PREVENTION OF ELECTRO STATIC DISCHARGE (ESD) TO
ELECTROSTATICALLY SENSITIVE (ES) DEVICES 
5
 4 
HOW TO RECYCLE THE NICKEL-METAL HYDRIDEBATTERY
(U.S. ONLY) 
5
 5 
CAUTION FOR AC CORD (VJA0940 TYPE) (B only) 
6
 5.1. 
INFORMATION FOR YOUR SAFETY 
6
 5.2. 
CAUTION FOR AC MAINS LEAD 
6
 6 
SERVICE NOTES 
7
 6.1. 
WHEN REPLACING THE MAIN C.B.A. 
7
 6.2. 
SERVICE POSITION 
7
 6.3. 
HOW TO DISCHARGE THE CHARGING CAPACITOR
ON MAIN C.B.A. 
8
 6.4. 
CLEANING LENS AND OPTICAL VIEWFINDER 
8
 7 
SCHEMATIC DIAGRAMS 
9
 7.1. 
ANALOG CIRCUIT BLOCK DIAGRAM 
9
 7.2. 
ASIC/CPU CIRCUIT BLOCK DIAGRAM 
9
 7.3. 
LCD CIRCUIT BLOCK DIAGRAM 
10
 7.4. 
LENS CIRCUIT BLOCK DIAGRAM 
10
 7.5. 
POWER CIRCUIT BLOCK DIAGRAM 
11
 7.6. 
RTC CIRCUIT BLOCK DIAGRAM 
11
 7.7. 
MOBILE PHONE CIRCUIT BLOCK DIAGRAM 
11
 7.8. 
MAIN SCHEMATIC DIAGRAM 
12
 8 
CIRCUIT BOARD ASSEMBLIES 
19
 8.1. 
MAIN C.B.A. 
19
 9 
REPLACEMENT PARTS LIST 
23
 9.1. 
ELECTRICAL REPLACEMENT PARTS LIST 
23
CONTENTS
 Page 
Page
2
DMC-LC20PP / DMC-LC20PM / DMC-LC20E / DMC-LC20B / DMC-LC20A / DMC-LC20EN / DMC-LC20KR
1 INTRODUCTION
1.1. INTRODUCTION
This service manual contains technical information, which allow service personnel’s to understand and service this model.
Please place orders using the parts list and not the drawing reference numbers.
If the circuit is changed or modified, the information will be followed by service manual to be controlled with original service manual.
IMPOTANT NOTICE 1: (Other than U.S.A. and Canadian Market)
 1. The service manual does not contain the following information, because of the impossibility of servicing at component level.
 a. Schematic diagram, Block Diagram and C.B.A. layout of Main C.B.A.
 b. Parts list for individual parts of Main C.B.A.
When a part replacement is required for repairing Main C.B.A., replace as an assembled parts. (Main C.B.A.)
 2. The following category is/are recycle module part. please send it/them to Central Repair Center.
    
·
    
MAIN C.B.A. (ES610-77) : For DMC-LC20E/B/A/EN (Excluding replacement of Lithium Battery)
IMPOTANT NOTICE 2:
The following listed category is/are not repairable at component level.
    
·
    
Lens unit (1)
1.2. HOW TO DEFINE THE MODEL SUFFIX (NTSC or PAL model)
There are only two kinds of DMC-LC20, one is the DMC-LC20PP/PM/KR (NTSC model) and the other one is DMC-LC20E/B/A/EN
(PAL models), in terms of the unit itself, regardless colours.
What is the difference is that the data, which is stored in Flash ROM located on MAIN C.B.A.
To define the unit to be serviced, refer to the safety registration mark on the name plate which is putted on the bottom side of
the Unit.
3
DMC-LC20PP / DMC-LC20PM / DMC-LC20E / DMC-LC20B / DMC-LC20A / DMC-LC20EN / DMC-LC20KR
2 SAFETY PRECAUTIONS
2.1. GENERAL GUIDELINES
 1. IMPORTANT SAFETY NOTICE
There are special components used in this equipment
which are important for safety. These parts are marked by
in the Schematic Diagrams, Circuit Board Layout,
Exploded Views and Replacement Parts List. It is essential
that
these
critical
parts
should
be
replaced
with
manufacturer’s specified parts to prevent X-RADIATION,
shock, fire, or other hazards. Do not modify the original
design without permission of manufacturer.
 2. An Isolation Transformer should always be used during the
servicing of AC Adaptor whose chassis is not isolated from
the AC power line. Use a transformer of adequate power
rating as this protects the technician from accidents
resulting in personal injury from electrical shocks. It will also
protect AC Adaptor from being damaged by accidental
shorting that may occur during servicing.
 3. When servicing, observe the original lead dress. If a short
circuit is found, replace all parts which have been
overheated or damaged by the short circuit.
 4. After servicing, see to it that all the protective devices such
as insulation barriers, insulation papers shields are properly
installed.
 5. After servicing, make the following leakage current checks
to prevent the customer from being exposed to shock
hazards.
2.2. LEAKAGE CURRENT COLD
CHECK
 1. Unplug the AC cord and connect a jumper between the two
prongs on the plug.
 2. Measure the resistance value, with an ohmmeter, between
the jumpered AC plug and each exposed metallic cabinet
part on the equipment such as screwheads, connectors,
control shafts, etc. When the exposed metallic part has a
return path to the chassis, the reading should be between 1
M
and 5.2 M
. When the exposed metal does not have a
return path to the chassis, the reading must be infinity.
2.3. LEAKAGE CURRENT HOT
CHECK (See Figure 1.)
 1. Plug the AC cord directly into the AC outlet. Do not use an
isolation transformer for this check.
 2. Connect a 1.5 k
, 10 W resistor, in parallel with a 0.15 µF
capacitor, between each exposed metallic part on the set
and a good earth ground, as shown in Figure 1.
 3. Use an AC voltmeter, with 1 k
/V or more sensitivity, to
measure the potential across the resistor.
 4. Check each exposed metallic part, and measure the
voltage at each point.
 5. Reverse the AC plug in the AC outlet and repeat each of the
above measurements.
 6. The potential at any point should not exceed 0.75 V RMS.
A leakage current tester (Simpson Model 229 or equivalent)
may be used to make the hot checks, leakage current must
not exceed 1/2 mA. In case a measurement is outside of
the limits specified, there is a possibility of a shock hazard,
and the equipment should be repaired and rechecked
before it is returned to the customer.
Figure. 1
4
DMC-LC20PP / DMC-LC20PM / DMC-LC20E / DMC-LC20B / DMC-LC20A / DMC-LC20EN / DMC-LC20KR
Page of 26
Display

Download Panasonic DMC-LC20PP / DMC-LC20PM / DMC-LC20E / DMC-LC20B / DMC-LC20A / DMC-LC20EN / DMC-LC20KR (serv.man2) Service Manual (Repair Manual)

Here you can read online and download Panasonic DMC-LC20PP / DMC-LC20PM / DMC-LC20E / DMC-LC20B / DMC-LC20A / DMC-LC20EN / DMC-LC20KR (serv.man2) Service Manual in PDF. DMC-LC20PP / DMC-LC20PM / DMC-LC20E / DMC-LC20B / DMC-LC20A / DMC-LC20EN / DMC-LC20KR (serv.man2) service manual will guide through the process and help you recover, restore, fix, disassemble and repair Panasonic DMC-LC20PP / DMC-LC20PM / DMC-LC20E / DMC-LC20B / DMC-LC20A / DMC-LC20EN / DMC-LC20KR (serv.man2) Digital Camera. Information contained in service manuals typically includes schematics / circuit diagrams, wiring diagrams, block diagrams, printed wiring boards, exploded views, parts list, disassembly / assembly, pcb.