MDS-MX101 - Sony Audio Service Manual (repair manual). Page 14

Read Sony MDS-MX101 Service Manual online

– 14 –
5-5.
TEMPERATURE  COMPENSATION  OFFSET
ADJUSTMENT
Save the temperature data at that time in the non-volatile memory
as 25
°
C reference data.
Notes:
1. Usually, do not perform this adjustment.
2. Perform this adjustment in an ambient temperature of 22 
°
C to
28 
°
C.  Perform it immediately after the power is turned on
when the internal temperature of the unit is the same as the
ambient temperature of 22 
°
C to 28 
°
C.
3. When D101 has been replaced, perform this adjustment after
the temperature of this part has become the ambient tempera-
ture.
Adjusting Method:
1. Press the  
= 0 button or ) + button and display
“TEMP ADJUST”.
2. Press the  YES  button and select the “TEMP ADJUST” mode.
3. “TEMP = 
 ” and the current temperature a data will be dis-
played.
4. To save the data, press the YES button.
When not saving the data, press the EDIT/NO button.
5. When the YES button is pressed, “TEMP= 
  SAVE” will
be displayed for some time, followed by “TEMP ADJUST”.
When the  EDIT/NO  button is pressed, “TEMP ADJUST”
will be displayed immediately.
Specifications:
The temperature should be within “E0-EF”, “F0-FF”, “00-0F”,
“10-1F” and “20-2F”.
5-6.
LASER  POWER  ADJUSTMENT
Connection:
Adjusting Method:
1. Set the laser power meter on the objective lens of the optical
pick-up. (When it cannot be set properly, press
the CHARACER button or SCROLL button and move the
optical pick-up.)
Connect the digital voltmeter to CN110 pin 5  (I+3V) and
CN110 pin 4 (IOP) of the BD board.
2. Press the
= 0 button or ) + button and display
“LDPWR ADJUST”.
(Laser power: for adjustment)
3. Press the YES button and display “LD 0.9 mW $ 
”.
4. Press the
= 0 button or ) + button so that the
reading of the laser power meter becomes 0.82 to 0.91 mW.
Set the range control on the laser power meter to 10 mW, then
press the YES button to save the adjustment result in the non-
volatile memory.
(“LD SAVE $ 
” will be displayed for a moment.)
5. Then “LD 7.0 mW $ 
 ”will be displayed.
6. Press the
= 0 button or ) + button so that the
reading of the laser power meter becomes 6.9 to 7.1 mW, press
the YES button and save the adjustment result in the non-
volatile memory.
(“LD SAVE $ 
” will be displayed for a moment.)
Note:  Do not perform the emission with 7.0 mW more than 15
seconds continuously.
7. Press the
= 0 button or ) + button and display
“LDPWR CHECK”.
8. Press the YES button and display “LD 0.9 mW $ 
”.
Check that the reading of the laser power meter becomes 0.80
to 0.96 mW.
9. Press the YES button and display “LD 7.0 mW $ 
”.
Check that the reading of the laser power meter and digital
voltmeter satisfy the specified value.
Specification:
Laser power meter reading : 7.0 
±
 0.2 mW
Digital voltmeter reading
: Optical pick-up displayed value 
±
10%
10. Press the  EDIT/NO  button and display “LDPWR CHECK”,
and stop the laser emission.
(The  EDIT/NO  button is effective at all times to stop the
laser emission.)
Optical pick-up
objective lens
laser
power meter
KMS260A
27X40
B0825
lOP=82.5 mA in this case
lOP (mA) = Digital voltmeter reading (mV)/1 (
)
(Optical pick-up label)
+
BD board
digital voltmeter
CN110 pin 
5
 (I+3V)
CN110 pin 
4
 (IOP)
Page of 46
Display

Click on the first or last page to see other MDS-MX101 service manuals if exist.