MDS-JA555ES - Sony Audio Service Manual (repair manual). Page 6

Read Sony MDS-JA555ES Service Manual online

6
SECTION  1
SERVICING NOTE
1
 Remove the 16 screws (BVTT3 x 8) from the bottom plate. (Refer to Section 3 “Disassembly” Loading panel.) (page 14)
2
 Remove the bottom plate.
3
 Rotate the pully gear in the direction of the arrow A and open the tray in the direction of the arrow B.
4
 When checking the laser power, remove beforehand the loading panel by removing the two screws (M2.6) and sliding aside the loading
panel becouse the cable of the laser power meter can be pinched by the loading panel. (Refer to Section 3 “Disassembly” Loading
panel.) (page 14)
Forced Reset
Use this function when the MDS-JA555ES cannot be operated normally due to hung-up of the microprocessor.
It is recommended to use this function when you cannot exit the test mode or the retry-cause-display mode, or when the normal operation
cannot be performed after the MDS-JA555ES is disassembled once then re-assembled.
Procedure : Remove the AC power plug from the wall outlet.  Short-circuit pin-1 and pin-3 of CN703 on the BT board with a pair of
tweezers or the like, to discharge the back-up battery.
HOW TO OPEN THE DISC TRAY WHEN POWER SWITCH IS TURNED OFF, AND LASER POWER CHECK
A
B
Pulley gear 
Tray assembly
Two screws 
     (M2.6)
Remove the Loading panel
[BT board] (Conductor side)
CN703
JW790
JW791
1
3
BT701
Page of 88
Display

Click on the first or last page to see other MDS-JA555ES service manuals if exist.