ICF-R45, ICF-T45 - Sony Audio Service Manual (repair manual). Page 6

Read Sony ICF-R45 / ICF-T45 Service Manual online

ICF-R45/T45
6
 AM Section
0dB=1
µV
S1: v (EARPHONE)
S3: AM
 FM Section
S1: v (EARPHONE)
S3: FM
• Repeat the procedures in each adjustment several times, and the
frequency coverage and tracking adjustments should be finally
done by the trimmer capacitors.
AM IF ADJUSTMENT
Adjust for a maximum reading on level meter.
T1
455kHz
AM FREQUENCY COVERAGE  ADJUSTMENT
Adjust for a maximum reading on level meter.
L4
520kHz
CT1–1
1,650kHz
AM TRACKING ADJUSTMENT
Adjust for a maximum reading on level meter.
L1
600kHz
CT1–2
1,400kHz
FM FREQUENCY COVERAGE  ADJUSTMENT
Adjust for a maximum reading on level meter.
L3
75.0MHz
CT1–3
109.5MHz
FM TRACKING ADJUSTMENT
Adjust for a maximum reading on level meter.
L2
75MHz
CT1–4
109.5MHz
FM RF signal
generator
22.5kHz frequency 
deviation by 400Hz signal.
Output level : as low as possible
set
MAIN board
TP (FM IN)
set
16
v
 earphone jack
level meter
SECTION 3
ELECTRICAL ADJUSTMENTS
AM  RF signal
generator
30% amplitude modulation by 400Hz
signal.
Output level : as low as possible
Put the lead-wire
antenna close to 
the set.
Connection :
Timer Frequency Check
S3 : AM or FM
1. Confirm that the reading of the frequency counter is in the
standard value.
Standerd value : 538 – 636Hz
L1
CF2
C10
D3
C1
C31
L4
C2
R5
R18
R6
CF1
IC1
1
15
TP
(FM IN)
TP(FM IN)
Connection :
[MAIN BOARD] (SIDE B)
C11
R4
R2
R3
R11
R20
TP
(TIMER)
R13
4
R12
R17
R15
C30
L11
C29
C28
R16
C27
IC2
BLK
1
4
5
8
TP
(TIMER)
Frequency counter
[MAIN BOARD] (SIDE A)
Page of 14