Read Sony ICD-UX502 Service Manual online
ICD-UX502
17
4-14. SLEEP
It can change into the sleep state for standby current value mea-
surement.
It can change into the sleep state for standby current value mea-
surement.
Note: It cannot move to other modes from this mode.
Procedure:
1. Enter the test mode.
2. Press
1. Enter the test mode.
2. Press
the
[
>
] or [
.
] keys to select the “SLEEP”, and press
the [
N
/ENTER] key.
3. The sleep state selection screen is displayed.
This unit shifts to the sleep state by pressing the [
N
/ENTER]
key again.
(Displayed characters/values in the following fi gure are ex-
ample)
ample)
<SLEEP>
SLEEP:NORMAL
Excuting...
SLEEP:NORMAL
Excuting...
LCD Display
Releasing method:
Remove battery.
Remove battery.
4-15. BATT
LIFE
Not used for the servicing.
4-16. WRITER
VER
Not used for the servicing.
4-17. LREC
LOG
Not used for the servicing.
4-18. LREC LOG Clear
Not used for the servicing.
Not used for the servicing.
4-19. MENU
INIT
This unit can return to the factory shipment settings.
Procedure:
1. Enter the test mode.
2. Press the [
1. Enter the test mode.
2. Press the [
>
] or [
.
] keys to select the “MENU INIT”, and
press the [
N
/ENTER] key.
3. Initialization is performed.
“Success” is displayed, and this unit reboots.