4-10. SIN
Sine wave can be outputted.
Sine wave can be outputted.
Procedure:
1. Enter the test mode.
2. Press the [
1. Enter the test mode.
2. Press the [
v
] or [
V
] keys to select the “SIN”, and press the
[
N
] key.
3. Sine wave is outputted.
(Displayed characters/values in the following fi gure are ex-
ample)
ample)
<SIN>
Sin: Infinity zero
Volume : 10
Sin: Infinity zero
Volume : 10
LCD Display
[FF]/[FR]
Infinity zero
Sine wave change
50Hz
100Hz
200Hz
1kHz
20kHz
10kHz
8.5kHz
1kHz Lch
1kHz Rch
Sweep
Key input settings under this mode of operation:
[
>
] or [
.
] : Sine wave change
[VOL +]
: Volume up
[VOL –]
: Volume down
Releasing method:
Press the [STOP/
Press the [STOP/
x
] key, return to test mode menu.
4-11. eMMC
Verify
Not used for the servicing.
4-12. File Sys Check
The fi rmware check can be performed.
The fi rmware check can be performed.
Procedure:
1. Enter the test mode.
2. Press the [
1. Enter the test mode.
2. Press the [
v
] or [
V
] keys to select the “File Sys Check”, and
press the [
N
] key.
3. Press the [
N
] key again, and the fi rmware checked.
(Displayed characters/values in the following fi gure are ex-
ample)
ample)
<File Sys Check>
Result : OK
Result : OK
LCD Display
4. Firmware is normal when “Result : OK” is displayed, and this
unit is reboots.
Firmware is abnormal when “Result : NG” is displayed. Press
the [STOP/
the [STOP/
x
] key, return to test mode menu.
4-13. Menu
Init
The menu settings of this unit can be return to the shipment set-
tings.
tings.
Procedure:
1. Enter the test mode.
2. Press
1. Enter the test mode.
2. Press
the
[
v
] or [
V
] keys to select the “Menu Init”, and press
the [
N
] key.
3. Press the [
N
] key again, and the initialization is performed.
(Displayed characters/values in the following fi gure are ex-
ample)
ample)
<Menu Init>
Success
Success
LCD Display
Releasing method:
Press the [STOP/
Press the [STOP/
x
] key, return to test mode menu.
4-14. Factory
Ship
This unit can return to the factory shipment settings.
Procedure:
1. Enter the test mode.
2. Press
1. Enter the test mode.
2. Press
the
[
v
] or [
V
] keys to select the “Factory Ship”, and press
the [
N
] key.
3. Press the [
N
] key again, and the initialization is performed.
(Displayed characters/values in the following fi gure are ex-
ample)
ample)
<Factory Ship>
Execute...
LCD Display
4. This unit is reboots, then the “Set Date&Time?” confi rmation
message appears.
Click on the first or last page to see other ICD-SX1000 / ICD-SX733 / ICD-SX733D / ICD-SX734 service manuals if exist.