17
4-6. Lcd/Led/Light
The lighting check of LCD can be performed.
Procedure:
1.  Enter the test mode.
2. Press 
the 
[
v
] or [
V
] keys to select the “Lcd/Led/Light”, and 
press the [
N
] key.
3.  LCD display pattern is displayed as shown in the following 
fi gure.
 
(Displayed characters/values in the following fi gure are ex-
ample)
LCD Display Pattern
All segments ON
Display pattern 2
All segments OFF
Display pattern 1
Peak
LED
(SX1000 only)
Recording
LED
Access
LED
 
Key input settings under this mode of operation:
 
[
>
] or [
.
: Display pattern change
 
[TRACK MARK] : Back light ON/OFF change
 
[
v
: All the LED lights up
 
[
V
: All the LED put out the lights.
Releasing method:
Press the [STOP/
x
] key, return to test mode menu.
4-7. INTMic Sens
Not used for the servicing.
4-8. INTMiC Clear
The internal stereo microphone sensitivity balance can be reset.
Note: When the internal stereo microphone is replaced, execute this mode.
Procedure:
1.  Enter the test mode.
2.  Press the [
v
] or [
V
] keys to select the “INTMiC Clear”, and 
press the [
N
] key.
3. Press 
the 
[
N
] key again, and the internal stereo microphone 
sensitivity balance is reset.
 
(Displayed characters/values in the following fi gure  are  ex-
ample)
<INTMiC Clear>
Result : OK
Lch:03h Rch:03h
[Stop]:Ret
LCD Display
Releasing method:
Press the [STOP/
x
] key, return to test mode menu.
4-9. Log Output
The failure analysis log can be outputted.
Procedure:
1.  Enter the test mode.
2. Press 
the 
[
v
] or [
V
] keys to select the “Log Output”, and press 
the [
N
] key.
3. Press 
the 
[
N
] key again, and the log fi le is output to the root 
folder of this unit.
 
(Displayed characters/values in the following fi gure  are  ex-
ample)
<Log Output>
Success
LCD Display
Root folder
XXXXXXXX: date of log outputted
Releasing method:
Press the [STOP/
x
] key, return to test mode menu.
Page of 26