ICD-P28 - Sony Audio Service Manual (repair manual). Page 10

Read Sony ICD-P28 Service Manual online

10
ICD-P28
9. USB test
• When the menu starts the USB self-check, either presence or
absence of the Vbus is judged.
(Vbus is present: “VBUS: ON”, Vbus is absent: “VBUS: OFF”)
• The USB driver always works regardless of presence or absence
of the USB signal only when Vbus is available during the USB
test. At this time, turning on  HOLD  causes the set to move to
the suspend state. Turning off the Vbus causes the set to return
to the test menu.
When Vbus is supplied with the menu displayed, the key will be
inoperative. Be sure to press  x•B  key before supplying.
10. Key durability test
• Input of  x•B  key causes the counter to be “- - - - - -”, entering
the test waiting mode. Input of  x•B  key causes the counter to
be “000000”, entering the key durability test mode.
In this mode, all key inputs and ON and OFF operations of the
slide switch are counted with a count display. Turn the power
off in order to exit this mode.
11. Menu reset
• Pressing the  x•B    key causes the set to enter the menu
initialization standby state.
• Once all the keys below are input in this condition, the EEPROM
will be initialized (The settings in the menu and the user name
will be defaulted.).
At the same time, the WakeUp signal is checked, too.
• Check keys (in any order of their inputs)
FOLDER  ,  DIVIDE  ,  DISPLAY  ,  MENU  ,  MIC SENS  ,
ERASE  ,  STOP  ,  REC/STOP  ,  PAUSE  ,
PLAY/STOP (ENTER)  ,  >  ,  .  ,  HOLD  on,
HOLD  off
(All is normally ended: –ALLOK–/NG in initialization write
to EEPROM: INIT. NG)
• Turn the power off in order to exit this mode.
• B
STOP
HOLD  ON
USB
VBUS
VBUS on
Suspend mode
Cut VBUS
Cut VBUS
OFF
VBUS
ON
LINK
PC
• B
STOP
COUNT
KEY
- - - - - -  
KEY
• B
00  00  00
KEY
KEY
Key endurance
test mode
any keys or
slid switchs on/off
00  00  01
• B
STOP
PUSH
After input all keys
Case of initial setting
and reset operated
normal end.
KEY
MENU
RST
INIT (Blink)
ALL
Ok
Page of 26